■COM1, 2
Register devices that are connected to COM1 and COM2.
Double-click the line with the same unit No. as the device to be registered, and setup window will be
displayed.
Up to 99 units can be registered and you can use filtering function to display the registered units.
Item
(a)
Unit No.
(b)
Name
(c)
Connection device
(d)
Expansion unit *1
*1 Only when the connection device is KW2G or KW2M. Do not set unless otherwise specified.
(a)
(b)
(c)
(d)
Description
Registered unit number is displayed.
Set name for the connected device.
<Set range> 32-letter or less
Set type for the connected device.
<Initial> KW1M
<Set range>
KW1M / KW2G / KW2M / KW4M / KW7M /
KW8M / KW9M / Remote I/O unit /Other
Set when the connection device has expansion unit(s).