Special Internal Relay(R) - Panasonic ELC500 User Manual

Table of Contents

Advertisement

9.5

Special Internal Relay(R)

ELC500 uses the following special interenal relays. Do not use them and do not write to the relay
number not listed.
These relays can be referred by MEWTOCOL. (It doesn't support MODBUS.)
Relay No.
R11030
LOG0 data transfer words
R11031
LOG1 data transfer words
R11032
LOG2 data transfer words
R1103E
LOG14 data transfer words
R1103F
LOG15 data transfer words
R11040
DT registers transfer 1
R11041
DT registers transfer 2
R11042
Demand data clear
Name
Number of data transfer words of logging device registered in LOG0
(<Initial> 0
Number of data transfer words of logging device registered in LOG1
(<Initial> 0
Number of data transfer words of logging device registered in LOG2
(<Initial> 0
Number of data transfer words of logging device registered in LOG14
(<Initial> 0
Number of data transfer words of logging device registered in LOG15
(<Initial> 0
Transfer collected logging data to DT register or not
(<Initial> 1
Transfer collected logging data to DT register or not
(<Initial> 1
Clear demand data or not (<Initial> 1
Description
0: 2 words, 1: 4 words)
0: 2 words, 1: 4 words)
0: 2 words, 1: 4 words)
0: 2 words, 1: 4 words)
0: 2 words, 1: 4 words)
0: not transfer, 1: transfer)
0: not transfer, 1: transfer)
174
ELC500 Control unit
0: not clear, 1: clear)

Advertisement

Table of Contents
loading

Table of Contents