6.2.1
Indicator description
The LED's are used for indicating states and faults of module. There is one power LED,
two link/activity LED's (one for each Ethernet connector), and 2 status LED's.
MAC Module Indicators
and label overview
System Failure
indicator
Line activity
indicators
TT3070-02GB
LED indicator descriptions - Covers both MAC and MIS/MIL.
LED Text
MAC / MIx
L/A IN /
L2
L/A OUT
L3
SF /
L1
BF /
ERR
PWR
Notes:
Blinking: Flashing with equal on and off periods of 200ms (2.5Hz). Single flash : Repeating on for 200ms
and off for 1s. Double flash : Two flashes with a period of 200ms followed by 1s off period. Triple flash :
Three flashes with a period of 200ms followed by 1s off period. Flickering : Rapid flashing with a period of
approx. 50ms (10 Hz).
6.2.2
Mechanical installation
The network cables must be connected to the two M12 connectors (marked "L/A IN"
and "L/A OUT") at the MAC module and "CN2" and "CN3" at the MIS/MIL motors.
The cable from the IO CONTROLLER is connected to either of the two ports.
In the line topology, if there are more slave devices in the same line, the next slave device
is connected to the second port. If there is a redundant ring, the second port of the last
slave device is connected to the second port of the IO CONTROLLER. See also figure in
the introduction section. Standard CAT 5 STP cables can be used. It is not recommended
to use UTP cables in industrial environments, which is typically very noisy.
140
JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors

Commissioning

Bus Failure indicator
Power
indicator
MAC address
Hardware serial number
Colour Constant off
No valid Ethernet
Green
connection.
No valid Ethernet
Green
connection.
Red
No System failures System failures
Red
No Bus failures
Power is not
Green
applied.
MIS Motor Indicators
and label overview
Hardware serial number
Constant on
Blinking
Ethernet is
-
connected.
Ethernet
is
-
connected.
DCP signal
service is
initiated
No data
Bus failures
exchange
Power is applied
to both motor
-
and module.
Power indicator
Bus Failure indicator
System Failure indicator
Line activity indicator (CN2)
Line activity indicator (CN3)
MAC address
(placed at front)
Flickering
Activity on line
Activity on line
-
-
Power is applied to mod-
ule but no communica-
tion with motor