■LED indicators on the Sensor Communication Unit
Status
Description
[PWR] indicator
-
Not lit
Unit power OFF state
The unit power (24 VDC)
Lit
is supplied to the Slave
Unit.
[ERR] indicator
-
Not lit
No error
Communications Setting
Blinking
Error
Communications data
Single flash
error
Double
Application WDT timeout
flash
Flashing
Boot error
Lit
PDI WDT timeout
Status
Description
[L/A IN] indicator
Link not established in
-
Not lit
physical layer
In operation after
Flashing
establishing link
Link established in physical
Lit
layer
[RUN] indicator
Link not established in
-
Not lit
physical layer
Blinking
Pre-Operational state
Single flash
Safe-Operational state
Lit
Operational state
7. Connection Procedure
Status
Description
[L/A OUT] indicator
Link not established in
-
Not lit
physical layer
In operation after
Flashing
establishing link
Link established in physical
Lit
layer
[SS] indicator
Power OFF or power
-
Not lit
supply ON is being initial
confirmed.
Normal: The number of
Lit
connected Sensors agrees
with the setting.
Sensor Error: The number
Lit
of connected Sensors is
different from the setting.