Predator-Dualview Installation Manual V2.1.21.1
5 Connections to Predators with HMA
When the HMA (Hinged Mount Adaptor) is fitted to the Predator, the 'Predator Composite Cable' is not used.
Connections between the power supply and Predator use conventional cables as detailed below.
30Vdc Power connections between Predator PSU and Predator that is fitted with HMA
Ethernet connections between Predator PSU and Predator that is fitted with HMA.
The Ethernet connection uses standard CAT5, CAT5e or CAT6 cables fitted with RJ45 connectors.
Gain access to connectors in the HMA
•
Ensure that the fixed part of the HMA is securely bolted to the top of the pole.
•
The hinged part of the HMA (Hinged Mount Adapter) is fastened to the fixed part using three M8x25
long hex head bolts. Use a spanner (13mm) to remove the three bolts. Each bolt is fitted with a
split spring lock washer, a plain metal washer (which prevents the split washer from damaging the
fibre washer) and a fibre washer (which prevents the paint on the hinged part from being damaged
unnecessarily.
Cable Size
No IR
0.75mm²
85m
1.00mm²
113m
1.25mm²
141m
1.50mm²
170m
2.50mm²
283m
3.00mm²
340m
4.00mm²
450m
RJ45
CAT5, CAT5e, CAT6 Cable
Pin 1
White with Orange Band
Pin 2
Pin 3
White with Green Band
Pin 4
Pin 5
Pin 6
Pin 7
White with Brown Band
Pin 8
© 360 Vision Technology Ltd.
SIR110
SIR140WL
32m
43m
54m
65m
108m
130m
173m
Orange
Blue
White with Blue Band
Green
Brown
SIR160
32m
30m
43m
40m
54m
50m
65m
60m
108m
100m
130m
120m
173m
160m
Signal
Tx+
Tx-
Rx+
Rx-
Page 8