  • Page 1 V12_1_129_03 Page 1 of 49 © 360 Vision Technology Ltd...
  • Page 2: Table Of Contents

    9 Invictus OSD .............................. 16 9.1 PIN Number ............................16 10 OSD Operation/Navigation ........................17 11 Locating the Invictus Hybrid on your Network ................... 24 12 Connecting to the Invictus Hybrid......................24 12, 1 Live View ............................26 12.1.1 Live Video ............................. 26 12.1.2 Status ..........................
  • Page 3: Safety And Precautions

    7. To prevent risk of injury caused by the lnvictus hybrid or mounting options becoming detached, fit a suitable safety chain or lanyard. 8. Use only 360 Vision lnvictus Hybrid power supplies. These have suitable terminals for all the wires in the lnvictus composite cable.
  • Page 4: Bracket Dimensional Drawing

    3. Bracket Dimensional Drawing V12_1_129_03 Page 4 of 49 Invictus Wall Bracket Invictus Corner Bracket Invictus PMB Bracket © 360 Vision Technology Ltd...
  • Page 5: Connections

    GLANDS:Face downwards, unused glands must be sealed. ELECTRICAL CONNECTIONS:Connecting the main power. MAININPUT 200-240VAC L=LIVE (BROWN) 200-240VAC 50/60Hz E=EARTH (GREEN/YELLOW) N=NEUTRAL (BLUE) SAFETY: ENSURE MAINS INPUT AND EACH CONNECTION ARE SECURELY CONNECTED AND STRAIN RELIEVED FUSE PROTECTION: MAINS UNPUT FUSE 1.6AF © 360 Vision Technology Ltd...
  • Page 6 GLANDS:Face downwards, unused glands must be sealed. ELECTRICAL CONNECTIONS:Connecting the main power. MAININPUT 200-240VAC L=LIVE (BROWN) 200-240VAC 50/60Hz E=EARTH (GREEN/YELLOW) N=NEUTRAL (BLUE) SAFETY: ENSURE MAINS INPUT AND EACH CONNECTION ARE SECURELY CONNECTED AND STRAIN RELIEVED FUSE PROTECTION: MAINS UNPUT FUSE 1.6AF © 360 Vision Technology Ltd...
  • Page 7: Standalone Alarmcard Setup

    Connect RS485 to camera to CON5 Protocol/Alarm settings Relay Output Use CON4 to set protocol and camera Use CON3 for relay output. alarm behavior (see page 9) Alarm Inputs Use CON 1 for volt free alarm inputs © 360 Vision Technology Ltd...
  • Page 8 V12_1_129_03 Page 8 of 49 © 360 Vision Technology Ltd...
  • Page 9 V12_1_129_03 Page 9 of 49 © 360 Vision Technology Ltd...
  • Page 10 SAFETY: ENSURE MAINS INPUT AND EACH CONNECTION ARE SECURELY CONNECTED AND STRAIN RELIEVED FUSE PROTECTION: MAINS UNPUT FUSE 1.6AF 360Vision Technology, 7 Seymour Court Manor Park, Runcorn, Cheshire, WA7 1SY, Tel +44 (0)1928 570000. www.360visiontechnology.com © 360 Vision Technology Ltd...
  • Page 11: Invictus Washer/Nozzle Bracket

    V12_1_129_03 Page 11 of 49 Water Jet direction (Vertical) Adjustable Nozzle Tube Nozzle Bracket located Fit M8 Plain Washer Between Nozzle bracket and Invictus mounting base. © 360 Vision Technology Ltd...
  • Page 12: Connections 1D Invictus With Hma

    360 blanking grommet must be fitted to the hole not used. Once all cables are terminated carefully hinge the unit back over and tighten the 3 HMA bolts back up to compress the gasket down. Recommended Cable Diameter/Distance (Exceeding these will cause the Invictus to not work) Camera current draw table © 360 Vision Technology Ltd...
  • Page 13 Connect Ethernet cable to HD HMA lnvictus connection board using a RJ45 connector (CON4) Please make sure there is adequate spare cable (20cm) for when the camera is resting on the lanyard, failure to do this could damage the connector circuit board. © 360 Vision Technology Ltd...
  • Page 14 CONNECTIONS:Connecting the main power. Connect Ethernet cable only MAININPUT 200-240VAC L=LIVE (BROWN) 200-240VAC 50/60Hz E=EARTH (GREEN/YELLOW) N=NEUTRAL (BLUE) SAFETY: ENSURE MAINS INPUT AND EACH CONNECTION ARE SECURELY CONNECTED AND STRAIN RELIEVED FUSE PROTECTION: MAINS UNPUT FUSE 1.6AF © 360 Vision Technology Ltd...
  • Page 15: Basic Twisted Pair/Rs485 Data Wiring

    V12_1_129_03 Page 15 of 49 I nvictus Hybrid Analogue lnstallation Configuration sectio n © 360 Vision Technology Ltd...
  • Page 16: Invictus Osd

    V12_1_129_03 Page 16 of 49 © 360 Vision Technology Ltd...
  • Page 17: Osd Operation/Navigation

    OSD (On screen display) is accessed by defining / programming preset 6 & 95. • Use the joystick up, down, left, right, to navigate the menu. Use the joystick zoom in to highlight / select an option. • • Use joystick left and right to increment/decrement numbers © 360 Vision Technology Ltd...
  • Page 18 V12_1_129_03 Page 18 of 49 Pin Numbers Engineer Level Operators: 360 or 426 or 180 Controllers: 1379 or 9731 Engineers: 5498 © 360 Vision Technology Ltd...
  • Page 19 The camera will perform an ACTION (goto preset, start preset or mimic tour), after a period of inactivity. Use the NUMBER option to set which preset or tour to start, and the DELAY MINUTES/SECONDS to input the inactivity time period. © 360 Vision Technology Ltd...
  • Page 20 Do not use if the system doesn't require a response as it will have an effect on the telemetry control of the cameras • Pelco Static Mode -Disables PTZ control • FV White Lights - Used when using Forward Vision protocol, can be used to select what lamps are controlled from the lamp command © 360 Vision Technology Ltd...
  • Page 21 • Brightness - Can be used to artificially brighten an image options are Bright, Normal and Medium. • Bright Control - Options are normal or automatic activation. © 360 Vision Technology Ltd...
  • Page 22 • White When Alarm - Set if white lights are to be used if an alarm is triggered. This feature works with 360 Standalone alarm card or 360 Vision Matrix only. • White Time out - Use if a white light timer is required. Default is on.
  • Page 23 • 80 % lamp intensity • 100 % lamp intensity • video switch • white day • ir-mono • mono • normal night • wash on • wash off • low power on • low power off © 360 Vision Technology Ltd...
  • Page 24 V12_1_129_03 Page 24 of 49 © 360 Vision Technology Ltd...
  • Page 25: Locating The Invictus Hybrid On Your Network

    Invictus Hybrid. Note the ports used by the Invictus Hybrid are :- 12 Connecting to the Invictus Hybrid Type in the IP address of the Invictus Hybrid into the address bar of Mozilla Firefox. The web page of the camera will appear.
  • Page 26: Live View

    Preset Seek/Define - This will allow admin and operator user levels to seek or define presets (Viewer user level can only seek presets). ( See Advanced Features - Presets - page 31) List all presets - Use to show all presets o programmed presets in drop down selection box. © 360 Vision Technology Ltd...
  • Page 27: Status

    V12_1_129_03 Page 27 of 49 © 360 Vision Technology Ltd...
  • Page 28: Settings

    • Text - Selecting this option will show the selected text on the video stream. Position available are top left or right of the image. • Detailed info - This will show the information about the stream on the video © 360 Vision Technology Ltd...
  • Page 29: Video Advanced

    Concurrent Uni/Multicast - Enable to allow concurrent unicast/multicast streams. RTSP protocols allow 'multicast' or 'unicast' transmission. In addition to the 'multicast' feature being available on the lnvictus, the 'multicast' feature must also be available on the receiving device. © 360 Vision Technology Ltd...
  • Page 30 Option allows the user to set the video streamer version. Options are original and 2016a. OK to program the new settings into the lnvictus Hybrid. Cancel to abandon the changes to the advanced video settings. Default is used to factory reset the video stream settings. © 360 Vision Technology Ltd...
  • Page 31: Advanced Features

    PTZ -The camera can be set to pan, tilt and zoom or not. This can be used to operate the sensor or lamp function. Use the Seek preset button to test the preset. Define preset button to set the above parameters. Delete preset to remove the preset © 360 Vision Technology Ltd...
  • Page 32 Home action - This sends the camera to a preset, tour or mimic. • Home Number - This sets the preset, tour or mimic the camera will go to / start. • Home timer - this sets the time for the period of inactivity. © 360 Vision Technology Ltd...
  • Page 33: Camera

    Auto Focus/Iris on PTZ -Auto focus / iris will activate when PTZ is used, can be switched off. Default is • Fast Shutter- Select fast shutter if using the lnvictus Hybrid camera on an ANPR system. Default is off. (See page 45 for table of options) © 360 Vision Technology Ltd...
  • Page 34 Night HLC Level - Set a value to help mask high intensity light sources, options are low, medium and high. • Night HLC Mask - Sets a mask for the light source, options are 1 (white) to 15 (grey). © 360 Vision Technology Ltd...
  • Page 35: Date/Time

    Time in Camera - Cannot be edited, shows the current date and time of the camera. Date Format - Select from the drop down the date format. Time Format - Choose 24hr or 12hr time display. © 360 Vision Technology Ltd...
  • Page 36: Network

    • Default Recovery - Inhibit Multiple Power Cycle Method, disables the network recovery process (See Network Recovery - page 40) • NTP Server - Input the address of the time server required, default is pool.ntp.org. © 360 Vision Technology Ltd...
  • Page 37: Interfaces

    • Authentication - Tick to enable 802.1x Options to choose MD5 or TLS, PEAP and option to add user name / password. • SNMP - Tick to enable SNMP default is disabled. OK to apply the new settings into the Invictus Hybrid. Cancel to abandon the changes to the network settings.
  • Page 38 • UUID Format - VMS may require this setting to be changed to connect to the camera. • Fixed Preset Location - Some of the pre programmed presets are moved to lower presets numbers. OK to apply the new settings into the Invictus Hybrid Cancel to abandon the changes to the settings...
  • Page 39: Add/Edit Users

    The admin user login password, can also be changed here. The web page admin password is also the ONVIF admin password. Care must be taken, when changing the admin password. There is no way of recovering the Invictus Hybrid admin password if forgotten. © 360 Vision Technology Ltd...
  • Page 40: Maintenance

    The lnvictus camera will re-boot once the update has been performed. DO NOT interfere with this process as it may stop the camera from working. Visit the 360 Vision Technology web site or contact 360 Vision Technical Support for the link to the update application & codec update files.
  • Page 41: Browser

    • Network Latency - Adjust Video player latency/buffer. Download - Download video plugin from the camera. • OK to apply the new settings into the lnvictus Hybrid. Cancel to abandon the changes to the settings. © 360 Vision Technology Ltd...
  • Page 42: Network Settings Recovery

    Repeat the above five times. On the final power ON, leave the power switched on for at least 5 minutes to allow the lnvictus Hybrid to initialise. (See section Locating the lnvictus Hybrid on your Network - page 24) © 360 Vision Technology Ltd...
  • Page 43: Special Presets

    360 Vision or 3rd party bracket/mounts and that any cable glands are also watertight or sealed with adequate weather proof sealant - failure to do so will invalidate the 360 Vision 3 year warranty © 360 Vision Technology Ltd...
  • Page 44: Storage And Handling

    V12_1_129_03 Page 44 of 49 © 360 Vision Technology Ltd...
  • Page 45: White Balance And Fast Shutter Options

    V12_1_129_03 Page 45 of 49 © 360 Vision Technology Ltd...
  • Page 46: White Balance Photo Biological Safety Precaution

    Lighting options: SIR200, SIR275, SIR250WL, SIR400, SIR550S, 400SWL, SIR100W200N The lighting options listed above fulfil the requirements for photo-biological safety according to IEC/EN 62471 (risk group2). Avoid prolonged eye exposure, do not stare at operating lamp. © 360 Vision Technology Ltd...
  • Page 47: Recording And Recording Browser

    At preset – Start recording when the camera gets to a specific preset, tour or mimic.  Attack Detect – Start recording if the camera is attacked  Schedule Edit – Setup a recording schedule (See below)  Lifetime – Recording schedule will stop after this period. © 360 Vision Technology Ltd...
  • Page 48 Once your options have been selected in the filter click on Update and the display will show the results based on the files currently on the cameras internal storage device which comply with the filter settings. © 360 Vision Technology Ltd...