POSSIBLE CAUSE: Excessively dry or excessive high humidity and high tension conditions causing cable tie and
tool to be locked onto the bundle.
CORRECTIVE ACTION: Press the "Silence" icon to turn the alarm signal "off". Lower the tension setting on the
tool by turning the tension adjustment knob counter clockwise 2 clicks.
Pull the trigger to cut the tie and eject the tip from the tool. Reset the tension by turning the tension adjustment
clockwise 2 clicks. If the message remains, the system will not operate. Write down the message and notify the
maintenance department.
PREVENTION: Control Humidity of ties.
ERROR 17 – Full tip collector
POSSIBLE CAUSE: Tip collector is full and contains 300 tips.
PA27647A01_05
OPERATION MANUAL
ENGLISH
ERROR > HELP
RE-ADJUST TENSION SETTING
AIR BURST
LOAD
PREVIOUS
MAINTENANCE
Help Screen Step 3
Fig. 19
ERROR 17 > FULL TIP COLLECTOR
EMPTY. PRESS BACK TO CONTINUE
AIR BURST
LOAD
SILENCE
MAINTENANCE
BACK