Panduit PAT1M4.0 Operation Manual page 45

Automatic cable tie installation tools pdm4.0: dispenser phm: feeder hoses
Table of Contents

Advertisement

© Panduit Corp. 2018
POSSIBLE CAUSE: This message appears when the cable tie advances to the tool sensor area of the tool and
remains there. When this occurs, the tool will not actuate again until the cable tie is cleared from the tool.
CORRECTIVE ACTION: Press the "Silence" icon to turn the alarm signal "off". Disconnect feeder hose from
tool. Look for cable tie in tool and remove cable tie, if present. Reconnect feeder hose, and resume operation. If
cable tie is not found, reconnect feeder hose. Straighten the feeder hose to eliminate any bends or twists and point
the tool away from yourself and others. Press the "Air burst" icon to provide a burst of air to dislodge and advance
the cable tie to the jaw area of the tool. The "Air Burst" icon can be pressed again if the cable tie does not advance
to the jaw area. When the cable tie is advanced to the tool jaw area, the "Tie in tool" message will appear and the
buzzer will sound. Press the "Silence" icon to turn the alarm signal "off". Remove the cable tie from the jaw area
and then press the "Back" icon.
If the cable tie does not advance to the tool jaw area after depressing the "Air Burst" icon several times, replace
the feeder hose with another and notify your maintenance department.
PREVENTION: Always remove the cable tie from the jaw area of the tool if the cycle is not completed (cable tie
did not wrap and tension around the bundle). Always have the air supply at the recommended pressure setting and
avoid severe bends in the feeder hose.
ERROR 13 - Detent sensor blocked or dirty
POSSIBLE CAUSE: Most likely, the tip collector is too full. The detent sensor lens may be blocked by the detent
cam, a foreign object, or the lens is dirty.
CORRECTIVE ACTION: Press the "Silence" icon to turn the alarm signal "off".
PA27647A01_05
OPERATION MANUAL
ENGLISH
Help Screen Step 2
ERROR > HELP
PRESS AIR BURST, REMOVE TIE
AIR BURST
LOAD
MAINTENANCE
PREVIOUS
Help Screen Step 3
ERROR 13 > DETENT SENSOR
SENSOR DIRTY OR BLOCKED
AIR BURST
LOAD
MAINTENANCE
SILENCE
Error Screen
Page: 43 of 64
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
73
BACK
`
75
HELP
BACK
12-2018

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pat1.5m4.0Pat1m4.0-btPat1.5m4.0-bt

Table of Contents