Panduit PAT1M4.0 Operation Manual page 33

Automatic cable tie installation tools pdm4.0: dispenser phm: feeder hoses
Table of Contents

Advertisement

© Panduit Corp. 2018
CORRECTIVE ACTION: Press the "Silence" icon to turn the alarm signal "off". Close the cover. The rotary
receiver will not advance unless the cover is closed. Press the "Load" icon to load next cable tie into position in
the dispenser. Pressing the "Back" will return to the previous menu level.
PREVENTION: Keep the cover closed.
ERROR 3 - Check for low air pressure
POSSIBLE CAUSE: This message will be displayed if the incoming air pressure is too low, or not connected.
CORRECTIVE ACTION: Press the "Silence" icon to turn the alarm signal "off".
Increase the air pressure to 65 PSIG (4,5 bar). As you adjust the line pressure the value will be indicated in this
table as the before cycle pressure. The pressure during cycle is a snap shot of the line pressure when the secondary
airburst is active when the tool is applying a tie. Pressing the "Back" will return to the previous menu level.
PREVENTION: To prevent this problem from recurring, verify that the airline is connected, and the air pressure is
between 65 and 85 PSIG (4,5 and 5,8 bar), with a maximum 10 PSI (0,7 bar) drop.
PA27647A01_05
OPERATION MANUAL
ENGLISH
ERROR 3 > LOW PRESSURE
INCREASE AIR PRESSURE
AIR BURST
LOAD
SILENCE
MAINTENANCE
Error Screen
MAINTENANCE> LINE PRESSURE
PSI
BEFORE CYCLE
DURING CYCLE
Page: 31 of 64
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
36