PREVENTION: If the "Tie in hose" error appears, ALWAYS make sure the cable tie is found (when pressing air
burst) before resuming operation. Stay within recommended line pressures and remove any sharp bends in the
feeder hose. DO NOT drop additional ties in hose to verify that the hose is clear. The additional tie will only make
the problem worse.
ERROR 9 - Blocked or dirty exit sensor
POSSIBLE CAUSE: This will occur if the exit (optical) sensor in the PDM4.0 Dispenser becomes obstructed due
to a cable tie or excess debris (dirt, grime, etc.) on the lens. The cable tie will remain in the dispenser or the end of
the PHM Feeder Hose that is attached to the dispenser. When this occurs, the tool cannot be actuated until the
cable tie is cleared from the system or hose.
PA27647A01_05
OPERATION MANUAL
ENGLISH
ERROR 9 > EXIT SENSOR
SENSOR DIRTY OR BLOCKED
AIR BURST
LOAD
SILENCE
MAINTENANCE
Error Screen
ERROR > HELP
DETACH HOSE, REMOVE OBSTRUCTION
PREVIOUS
MAINTENANCE
Help Screen Step 1
ERROR > HELP
RE-ATTACH HOSE TO DISPENSER
PREVIOUS
MAINTENANCE
Help Screen Step 2