ERROR 6 - Tie in tool
POSSIBLE CAUSE: This occurs if the cable tie reaches the tool but is prevented from completing the cycle. This
may be due to a large air pressure drop, too large of a bundle, improper feeder hose connections, an obstruction
blocking the cable tie path, pushing the front jaw in at the start of the cycle, a severe bend or twist in the feeder
hose, or the tool jaws are opened during the cycle.
CORRECTIVE ACTION: Remove the cable tie and any obstruction from the jaw area. Pressing the "Back" will
return to the previous menu level. Resume operation.
PREVENTION: To prevent this problem from recurring, verify that the feeder hose connections are secure and that
there are no severe bends or twists in the feeder hose. Verify that the maximum bundle diameter does not exceed
.82" (21 mm) for the PAT1M4.0 Tool, and 1.31" (33 mm) for the PAT1.5M4.0 Tool. Also, verify that the air pressure
is between 65 and 85 PSIG (4,5 and 5,8 bar), with a maximum 10 PSI (0,7 bar) drop.
ERROR 7 - Tie in hose
PA27647A01_05
OPERATION MANUAL
ENGLISH
ERROR 6 > TIE IN TOOL
REMOVE TIE FROM TOOL JAW
AIR BURST
LOAD
SILENCE
MAINTENANCE
Error Screen
ERROR 7 > TIE IN HOSE
CLEAR TIE IN HOSE
AIR BURST
LOAD
SILENCE
MAINTENANCE
Error Screen
Page: 34 of 64
PAT1M4.0, PAT1M4.0-BT
PAT1.5M4.0, PAT1.5M4.0-BT,
PDM4.0, PHM
43
HELP
BACK
45
HELP
BACK
12-2018

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pat1.5m4.0Pat1m4.0-btPat1.5m4.0-bt

Table of Contents