ERROR 4 - Check for high air pressure
POSSIBLE CAUSE: This message will be displayed if the incoming air pressure is too high.
CORRECTIVE ACTION: Press the "Silence" icon to turn the alarm signal "off".
Decrease the air pressure to below 85 PSIG (5,8 bar). Pressing the "Back" will return to the previous menu level.
PREVENTION: To prevent this problem from recurring, verify that the air pressure is between 65 and 85 PSIG (4,5
and 5,8 bar).
ERROR 5 - Dispenser jam - check tie loading
PA27647A01_05
OPERATION MANUAL
ENGLISH
ERROR 4 > HIGH PRESSURE
DECREASE AIR PRESSURE
AIR BURST
LOAD
SILENCE
MAINTENANCE
Error Screen
MAINTENANCE> PRESSURE
PSI
BEFORE CYCLE
DURING CYCLE
ERROR 5 > DISPENSER JAM
CHECK TIE LOADING
AIR BURST
LOAD
SILENCE
MAINTENANCE
Error Screen