5 Installation
5.3
Preparing a VacuumCompatible N470 for Connecting to the
Electronics
Figure 10:
Assigning the stranded wires and the cable shield
Letter
a
b
c
Requirements
You have read and understood the general notes on installation (p. 17).
The cable on the air side of the N-470 is not connected to the electronics.
Tools and accessories
Suitable vacuum feedthrough
Air side and vacuum side connector (male or female) for vacuum feedthrough
K030B1063 air side cable (p. 13)
Suitable tools for wiring the connectors
22
Version: 1.2.0
Vacuum-compatible N-470: Connections for the vacuum feedthrough
1
Vacuum-side connector for the N-470's cables
2
Vacuum feedthrough
3
Connector for the K030B1063 air side cable (p. 13)
4
LEMO connector, 3-pin, see "Pin Assignment" (p. 46)
Wire color
Vacuumside
Airside
actuator cable
connecting cable
Red
White
Black
Brown
---
---
Function
Piezo voltage 0 to 80 V
Piezo voltage ground
Bare cable shield
MP125E
Signal
PIEZO+
PIEZO-
---
N470 Linear Actuator