Preparing A Vacuum-Compatible N-470 For Connecting To The Electronics - PI N470 Series User Manual

Linear actuator
Table of Contents

Advertisement

5 Installation
5.3
Preparing a Vacuum­Compatible N­470 for Connecting to the
Electronics
Figure 10:
Assigning the stranded wires and the cable shield
Letter
a
b
c
Requirements
 You have read and understood the general notes on installation (p. 17).
 The cable on the air side of the N-470 is not connected to the electronics.
Tools and accessories
Suitable vacuum feedthrough
Air side and vacuum side connector (male or female) for vacuum feedthrough
K030B1063 air side cable (p. 13)
Suitable tools for wiring the connectors
22
Version: 1.2.0
Vacuum-compatible N-470: Connections for the vacuum feedthrough
1
Vacuum-side connector for the N-470's cables
2
Vacuum feedthrough
3
Connector for the K030B1063 air side cable (p. 13)
4
LEMO connector, 3-pin, see "Pin Assignment" (p. 46)
Wire color
Vacuum­side
Air­side
actuator cable
connecting cable
Red
White
Black
Brown
---
---
Function
Piezo voltage 0 to 80 V
Piezo voltage ground
Bare cable shield
MP125E
Signal
PIEZO+
PIEZO-
---
N­470 Linear Actuator

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents