10 Technical Data
10.2

Step Size and Axial Force

The following graph shows the step size of the N-470 against various axial forces. The influence
of different axial forces on the step size is relatively minor. The active feed force is specified as
22 N (see "Technical Data" (p. 35)).
Figure 11:
N­470 Linear Actuator
Typical step size in nm vs. axial force in N
MP125E
Version: 1.2.0
39