10 Technical Data
10.6
Pin Assignment
A LEMO connector is used for connecting to the drive electronics:
Models that are not suitable for use in a vacuum: The connector is located directly on
the cable of the N-470.
Vacuum-compatible models: The connector is on the air-side cable (p. 13). The ends of
the cable on the vacuum and air side of the N-470 have stranded wires for connecting
to a vacuum feedthrough (p. 22).
Figure 19:
Pin
1
2
3
Cable shield
46
Version: 1.2.0
LEMO connector, 3-pin
Function
Input: Piezo + (0 to 80 V)
Input: Piezo - (GND)
Not connected
Connected to the connector
shell
Wire colors for vacuumcompatible models
Cable on the vacuum
side
Red
Black
---
Bare
MP125E
Cable on the air side
White
Brown
---
Bare
N470 Linear Actuator