Troubleshooting
Symptom
Battery Icon is displayed,
Display blank.
Meter does not latch for batching.
Slow or no fluid flow.
Meter inaccurate.
W A R N I N G
Do not repair or inspect meter while
pressurized. Do not operate meter with
damaged valves, controls or pumps.
Failure to comply may result in
serious injury or death.
Possible cause
Batteries are low
Meter asleep.
Loose battery connection.
Batteries dead.
Meter not in AUTO mode.
Meter not reset after prior batch.
Low batteries.
Filter is clogged.
Pump pressure is low.
Foreign material is jamming meter.
Scale factor not correct for fluid.
14
Remedy
Replace batteries
Push reset button.
Remove battery pack and check battery connection and push
reset button
Replace batteries and push reset button
Press AUTO button and program batch size
Press RESET button
Check for battery icon, replace batteries and push RESET
button
Clean or replace the filter in the swivel nut
Turn up the pump pressure
Contact your local distributor for repair
Enter program mode, check and reset program factor