Lincoln 905SF Installation And Maintenance Manual page 10

Electronic lube meter
Hide thumbs Also See for 905SF:
Table of Contents

Advertisement

Unit of measure
1 Select program mode.
!
Notice
Actual unit of measure is flashing
when programming mode is entered.
Meter has option of four different
units of measure from factory.
Scale factor digits
Programming display
2 Press the TOTAL button to toggle between
the four options; pt, qt, gal, l.
3 When the desired unit of measure is
displayed, press the RESET button.
4 If no scale factor changes are necessary,
refer to Save changes.
!
Notice
Unit of measure icon stops flash-
ing. If l, (liters), is selected, decimal point
begins to flash.
Changing the unit of measurement from
metric to English or from English to
metric clears the re-settable total and
accumulated total.
Scale factor
!
Notice
Changing scale factor changes ac-
curacy of meter, potentially causing it to
overfill or under fill. Potential for a
mechanical breakdown may exist.
1 Press the RESET button to advance
through the scale factor digits.
2 Press the TOTAL button to change the
selected number.
!
Notice
All digits can be scrolled between
0 and 9 except first. It can only be
scrolled from 0 to 1 or from 1 to 0.
Unit of
measurement
3 Press the RESET button to advance to the
next number in scale factor.
4 Repeat steps 2 and 3 for all five digits in
scale factor.
Save changes
1 Push and hold at the same time the
TOTAL and AUTO buttons.
2 The display will flash 3 times and go
blank.
3 Press the RESET button and the display
will turn back on.
Verify changes
1 Verify unit of measure is correct.
2 Push and hold the TOTAL button and
AUTO button together, to verify that the
scale factor is correct.