Page 1
Installation and maintenance guide Electronic lube meter Model 905SF, series “B” January 2014 Date of issue D A N G E R Form number 404128F Read manual prior to installation or use Section of this product. Keep manual nearby for Page future reference.
Please contact your This is the safety alert symbol. It is used local Lincoln distributor and refer to to alert you to potential physical injury Section K5, Page 31 for more details.
• Changeable units of measure W A R N I N G W A R N I N G • One programmable preset • Total and re-settable total Meter hazards This meter is not designed to dispense • Minimum 20,000 cycles on battery life Equipment misuse can cause the meter petroleum products or methanol based •...
Page 5
Meter buttons Meter display Used to enter the dispense batch quantity when in the EPM mode. Total is used to display the accumulated total of Total fluid dispensed, as well as the re-settable total Auto is used to enter and exit the manual or Auto batch mode.
Meter installation Flushing procedure W A R N I N G Relieve system pressure Pressurized equipment 1 Turn off the power supply to the pump or Do not clean, service or inspect any part close the shutoff valve. of meter while pressurized. 2 Dispense any fluid in the system into a Equipment stays pressurized Notice...
Meter operation Auto batch mode Notice Display resets and meter is now Manual mode ready for next batch to be dispensed. In the Manual Mode the meter operates as a free flow dispensing handle. Notice Keypad AUTO button is used to toggle between manual mode and batch mode.
Operating mode 2 RESET TOTAL displays the total fluid dis- functions pensed since the Re-settable Total was last set back to zero. 3 Press the RESET button while viewing Reset total to set it back to zero. Re-settable/accumulated 4 Release the RESET button to return to totals the operating display.
Service Change factory Changing the Batteries settings The battery compartment is located in the Low battery lower case on the underside of the trigger When the batteries need to be changed a guard. Each meter is calibrated at the factory for progression of warnings appears on the 1 Turn the unit over.
Page 10
Unit of measure Scale factor 1 Select program mode. Notice Notice Actual unit of measure is flashing Changing scale factor changes ac- when programming mode is entered. curacy of meter, potentially causing it to Meter has option of four different overfill or under fill.
Calculate scale factor Absolute scale factor test Notice 1 Run a measured amount of fluid through Original scale factor of meter was A scale factor is a number used to adjust the meter. written on trigger when calibrated at meter accuracy. The scale factor is set at the 2 If the meter delivers 4.20 qt.
Page 12
Dimensions 11 in. (0,27 m) 3.8 in. (0,09 m) 7 in. (0,17 m) Specifications D A N G E R Maximum flow 10 gal./min. (38 l/min.) Do not use unit with methanol based Minimum flow 0.25 gal./min. (1 l/min.) Operating pressure (maximum) 1,000 psi (69 bar) windshield washer fluid or other flam- mable liquids.
Page 13
Service parts Service parts Item no. Description Part number Nozzle 273862 Display assembly 274610 Rubber boot 274609 Trigger 272378 Solenoid 276319 Battery holder assembly 274632 Bottom case 272384 Meter body Not available Register assembly 274631 Gear service kit with o-ring 273059 Valve assembly 273061...
Page 14
Troubleshooting Symptom Possible cause Remedy Battery Icon is displayed, Batteries are low Replace batteries Display blank. Meter asleep. Push reset button. Loose battery connection. Remove battery pack and check battery connection and push reset button Batteries dead. Replace batteries and push reset button Meter does not latch for batching.
Customer service 314-679-4200 required. (international number 01-314-679-4200) In no event shall Lincoln be liable for inci- or you may also use our website dental or consequential damages. Lincoln’s www.lincolnindustrial.com liability for any claim for loss or damages...