vacon • 26
To restore parameters, write 0x64616F6C (ASCII "load") into the sub-index by using the SDO
protocol. Default object values are selected after reset. Restore all default parameter restores CiA-
402 default parameters (refer to Chapter 8.2.2.2). Bypass parameter set is described in Chapter 8.3.
Table 49: 0x1011 Restore default parameters
Index
0x1011
* The bypassed set disables the CIA- 402 drive profile and resets the PDO mapping to the vendor specific
configuration. See Chapter 8.2 and Chapter 8.3 for more information.
3
Sub-index
Name
0
Highest sub-index supported
Restore all default
1
parameters
Restore bypass parameter
4
set*
Restore Puller parameter
5
set
Restore Co-Extruder param-
6
eter set
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
CANopen protocol description
Data type
Access
UNSIGNED8
ro
UNSIGNED32
r/w
r/w
UNSIGNED32
r/w
UNSIGNED32
r/w
UNSIGNED32