8. Touch inside the Ignore Last Samples field and enter a value from 0 to 999.
9. Touch the Filter head signal checkbox to enable filtering of the head signal; then touch the
Train Filter button to automatically set up equalization on the currently acquired head
signal. See Train Filter in "PRML Channel Emulation" then touch Back
this setup. If you do not automatically train the filter, you need to perform steps 10 and 11 to
manually set up the equalization filter.
10. Touch inside the 3 dB Frequency field and enter a value from 1.0 MHz to 800 MHz using
the pop-up numeric keypad. See 3 dB Frequency in "PRML Channel Emulation" then touch
Back
to complete this setup.
11. Touch inside the Boost field and enter a value from 0 to 13 dB using the pop-up numeric
keypad. See Boost at fc in "PRML Channel Emulation" then touch Back
this setup.
12. Touch inside the Group Delay field and enter a value from 30.0% to +30.0% using the
pop-up numeric keypad. See Group Delay in "PRML Channel Emulation." This parameter
is not set by the "Train Filter" function.