Before Installation; Installation Regulations; Choice Of The Location; Type Plate - REMEHA Quinta Pro 30 Installation, User And Service Manual

High-efficiency wall-hung gas boiler
Hide thumbs Also See for Quinta Pro 30:
Table of Contents

Advertisement

5

Before installation

5.1

Installation regulations

5.2

Choice of the location

Fig.5
Position of type plate
Fig.6
Installation area
0
0 0
n . 1
m i
5.3

Ventilation

123157 - v.12 - 07022018
Warning
The installer must be registered with Gas Safe and have the cor­
rect ACS qualifications.
Important
Practical guidelines - see the latest version.
5.2.1
The type plate on top of the boiler features the boiler serial number and
important boiler specifications, for example the model and unit category.
The dF and dU codes are also stated on the type plate.
AD-0000013-02
5.2.2
Use the guidelines and the required installation space as a basis for de­
termining the correct place to install the boiler.
5 0
0
When determining the correct installation space, take account of the
permitted position of the flue gas discharge and/or air supply outlet.
Ensure that there is sufficient space around the boiler for good access
and ease of maintenance.
m i
Danger
n .
It is forbidden to store, even temporarily, combustible products
4 0
0
and substances in the boiler or near the boiler.
Warning
7 5
0
Caution
3 5
0
m i
n .
2 5
0
0
5 0
AD-0000014-02
The installation must comply with BS 5540 (part 1 + 2), BS 6644 and
IGUP/10.

Type plate

Boiler position

Fix the appliance to a solid wall capable of bearing the weight of
the boiler when full of water and fully equipped.
The boiler must be installed in a frost-free area.
The boiler must have an earthed electrical connection.
A connection to the drain must be present for the condensate
drain close to the boiler.
5 Before installation
21

Advertisement

Table of Contents
loading

Table of Contents