Modbus
Data type /
register
Size in bytes
1327
Unsigned / 2
1312
Float / 4
FST020 IP65 NEMA 4X
Operating Instructions, 09/2017, A5E41425845-AB
Parameter
Description
Clamp-on sen‐
Installed sensor
sor model
size.
Sensor crystal
Length of the
projection
crystal projec‐
tion onto the
emitting surface
of the sensor.
A.9 Modbus holding register tables
Default value
Value range /
[units]
Setting options
(units register)
20
● 0: None selected / Custom
sensor
● 1: A1H (High precision)
● 2: A2H (High precision)
● 3: A3H (High precision)
● 4: B1H (High precision)
● 5: B2H (High precision)
● 6: B3H (High precision)
● 7: C1H (High precision)
● 8: C2H (High precision)
● 9: D1H (High precision)
● 10: D2H (High precision)
● 11: D3H (High precision)
● 12: D4H (High precision)
● 13: A1 (Universal)
● 14: A2 (Universal)
● 15: B1 (Universal)
● 16: B2 (Universal)
● 17: B3 (Universal)
● 18: C1 (Universal)
● 19: C2 (Universal)
● 20: C3 (Universal)
● 21: D1 (Universal)
● 22: D2 (Universal)
● 23: D3 (Universal)
● 24: E1 (Universal)
● 25: E2 (Universal)
● 26: E3 (Universal)
● 27: 1 (High temperature)
● 28: 2 (High temperature)
● 29: 2A (High temperature)
● 30: 3 (High temperature)
● 31: 3A (High temperature)
● 32: 4 (High temperature)
● 33: 4A (High temperature)
0.03409
0.0 - 3.0
[m]
(8556)
Modbus communication
Access
level
Read /
write
Read /
write