No.
Description
r2132
CO: Actual alarm code
r2133
Fault value for float values
r2134
Alarm value for float values
r2135
CO/BO: Status word faults / alarms 2
r2136
Fault time removed in days
r2138
CO/BO: Control word, faults/alarms
r2139
CO/BO: Status word, faults/alarms 1
p2141
Speed threshold value 1 [rpm]
p2153
Speed actual value filter time constant [ms]
p2155
Speed threshold value 2 [rpm]
p2156
Switch-on delay comparison value reached [ms]
p2165
Load monitoring blocking monitoring upper
threshold [rpm]
p2168
Load monitoring blocking monitoring torque
threshold [Nm]
r2169
CO: Speed actual value smoothed signals [rpm]
p2170
Current threshold value [A]
p2171
Current threshold value reached delay time [ms]
p2172
DC-link voltage threshold [V]
p2174
Torque threshold value 1 [Nm]
p2191
Load monitoring torque threshold without load
[Nm]
p2194
Torque threshold value 2 [%]
p2195
Torque utilization switch-off delay [ms]
r2197
CO/BO: Status word monitoring functions 1
r2198
CO/BO: Status word monitoring 2
r2199
CO/BO: Status word monitoring 3
p2200
BI: Technology controller enable
p2201
CO: Techn. controller fixed value 1 [100 ≙ 100%]
p2202
CO: Techn. controller fixed value 2 [100 ≙ 100%]
...
...
p2215
CO: Techn. controller fixed value 15 [100 ≙
100%]
p2216
Techn. controller fixed value selection method
1
Direct selection
p2220
BI: Techn. controller fixed value selection bit 0
p2221
BI: Techn. controller fixed value selection bit 1
p2222
BI: Techn. controller fixed value selection bit 2
p2223
BI: Techn. controller fixed value selection bit 3
r2224
CO: Techn. controller fixed value active [100 ≙
100%]
SINAMICS G120C, FSD ... FSF inverters
Compact Operating Instructions, 11/2016, FW V4.7 SP6, A5E39339884B AA
2
Binary selection
4.2 Commissioning with BOP-2 operator panel
No.
Description
r2225
CO/BO: Techn. controller fixed value selection
status word
r2229
Techn. controller number currently
p2230
Techn. controller motorized potentiometer config-
uration
.00 Storage active
.02 Initial rounding active
.03 Non-volatile data save active for
p2230.0 = 1
.04 Ramp-function generator always active
r2231
Techn. controller motorized potentiometer set-
point memory
p2235
BI: Techn. controller motorized potentiometer
setpoint up
p2236
BI: Techn. controller motorized potentiometer
setpoint down
p2237
Techn. controller motorized potentiometer maxi-
mum value [%]
p2238
Techn. controller motorized potentiometer mini-
mum value [%]
p2240
Techn. controller motorized potentiometer start
value [%]
r2245
CO: Techn. controller motorized potentiometer
setpoint before RFG [100 ≙ 100%]
p2247
Techn. controller motorized potentiometer ramp-
up time [s]
p2248
Techn. controller motorized potentiometer ramp-
down time [s]
r2250
CO: Techn. controller motorized potentiometer
setpoint after RFG [100 ≙ 100%]
p2251
Techn. controller mode
0
Techn. controller as main speed setpoint
1
Techn. controller as additional speed set-
point
p2252
Technology controller configuration
.04 1 = ramp function generator (up/down) by-
pass deactivated
.05 1 = integrator for skip speeds active
.06 1 = do not display internal controller limita-
tion
p2253
CI: Techn. controller setpoint 1 [100 ≙ 100%]
p2254
CI: Techn. controller setpoint 2 [100 ≙ 100%]
p2255
Techn. controller setpoint 1 scaling [100 ≙ 100%]
p2256
Techn. controller setpoint 2 scaling [100 ≙ 100%]
p2257
Techn. controller ramp-up time [s]
p2258
Techn. controller ramp-down time [s]