Page 1
USBCam2 User Guide B1051061 Sirona Dental, Inc. 30-30 47 Avenue Long Island City, NY 11101 (718) 937-5765 (718) 937-5962 (fax) Sirona Dental GmbH Sirona Straße 1 5071 Wals bei Salzburg Austria PART NUMBER B1051061 REV. A...
Page 2
US D493,892 USBCAM® US 6,002,424; US 5,908,294 Positioning Systems US 6,811,312 Schick WiFi US 7,090,395; 6,091,982 Many of the designations used by manufacturers and sellers to distinguish their products are claimed as trademarks. Where those designations appear in this document, and Sirona Dental, Inc.
1.1. Purpose ............................1 1.2. Indications for Use ........................1 1.3. System Description ........................2 1.4. Getting the Best Images with USBCam2 .................. 3 2. Installation ..................4 2.1. What You Will Need to Complete this Section ................ 4 2.2. Before You Start Installing Software ..................4 2.3.
Page 4
List of Figures Figure 1. USB Cable Connectors ......................9 Figure 2. USBCam2 Listed in Device Manager ................. 9 Figure 3. Handpiece Holder Instrument Rail Installation ..............10 Figure 4. Handpiece Holder Wall Mounting Installation ..............11 Figure 5. Video Capture Window ..................... 13 Figure 6.
Page 5
When in use, the LEDs in the USBCam2 may generate surface temperatures in excess of 106° F (41° C). To avoid the potential risk of burn, do not use the USBCam2 in a single hand-held position for a prolonged period. As an additional safety measure, the USBCam2 is equipped with an Auto-Off feature.
Page 6
Installers to Ensure that USBCam2 Operates Optimally Installers must ensure that the USBCam2 provides the user with the optimal use of the equipment. This includes, but is not limited to, ensuring the system operates as described in this document.
Page 7
Product Manuals from Sirona Dental The contents of this manual are subject to change without prior notice. For the latest version of this user guide and other product manuals from Sirona Dental, please consult website: www.schickbysirona.com USBCam2 User Guide B1051061 Rev. A...
Page 8
Indicates the location of the Power On / Off button on the USBCam2 camera Indicates the location of the Freeze Frame Capture button on the USBCam2 camera Label Location The Schick logo and the following label can be found on the USBCam2 camera. B1051061 Rev. A USBCam2 User Guide...
Page 9
Sirona Dental and its Dealers are committed to complying with the Directive. WEEE Marking All Schick products subject to the WEEE Directive and shipped after August 13, 2005 will be compliant with the WEEE marking requirements. These products will be identified with the “crossed- out wheeled bin”...
Page 10
Information will include the different EEE components and materials as well as the location of substances in these items. The information will be provided as a printed document or in electronic media (on CD-ROM or by web download, for example). viii B1051061 Rev. A USBCam2 User Guide...
Page 11
USBCam2 USBCam2 with Handpiece Holder USBCam2 User Guide B1051061 Rev. A...
Page 12
(This page is intentionally left blank) B1051061 Rev. A USBCam2 User Guide...
• Automatically advances to capture the next video image (CDR DICOM). 1.2. Indications for Use USBCam2 is to be used as an intraoral video source and is indicated for individuals who may benefit from the addition of video images in intraoral dental examinations.
Windows Vista (32- or 64-bit) or Windows XP (32- or 64-bit) PC workstation, which provides the power source for the device. To turn on the USBCam2, press the Power button located near the base of the handpiece; pressing the button a second time turns the USBCam2 off (Figure 7).
Display tab. Color resolution can be checked by clicking Windows Start > Settings > Control Panel, double-clicking on Display, and then clicking on the Settings tab. Factory settings for the USBCam2 are: 30 frames-per-second frame rate, fixed white balance, and auto exposure. More information about video settings can be found in Sections B-1 and B-2.
EMC and EMI standards) 2.2. Before You Start Installing Software IMPORTANT! CDR users please do not connect the USBCam2 and cable to your computer until after you have installed the device driver and updated the DirectX files on your system. Procedures for installing these files can be found in this section.
Imaging) if it is running and verify that USBCam2 is NOT connected to the host computer. A. Insert the USBCam2 Driver CD. If the start page doesn’t start automatically, click Start, Run, and enter d:\CDR USBCam 2 Driver Setup (if your drive letter is different, use that one instead).
Page 18
A. Setup will copy the drivers to your workstation. B. If prompted, install Microsoft’s DirectX. A. Click Finish. B. Connect the USBCam2 camera to your computer. (For details, refer to Section 2.5) C. After a few seconds the message “Device driver software installed successfully”...
Imaging) if it is running and verify that USBCam2 is NOT connected to the host computer. A. Insert the USBCam2 Driver CD. If the setup doesn’t start automatically, click Start, Run, and enter d:\CDR USBCam 2 Driver Setup (if your drive letter is different, use that one instead).
Page 20
A. Setup will pre-install files to your workstation. B. If prompted, install Microsoft’s DirectX. A. Click Finish. B. Connect the USBCam2 camera to your computer. (For details, refer to Section 2.5.) C. The message, “Your new hardware is installed and ready to use” will appear momentarily in the Windows System tray.
2.5. Connecting the USBCam2 IMPORTANT! Do not connect the USBCam2 and cable to your computer until after you have successfully installed the USBCam2 driver, as described in the previous sections. The USB 2.0 cable used with the camera has a Series "A" USB connector on one side and a Series "B"...
PLEASE NOTE: When selecting the mounting option for your USBCam2, choose a location that offers easy access during patient exams and safe storage afterwards. In most practices, mounting the USBCam2 to the dental unit will provide the best all-around solution.
3. Using the holes on the back of the holder as guides, fasten the holder securely to the wall using 2 (#6 x 3/4) dry wall screws (not supplied) or other hardware appropriate to the mounting surface. Figure 4. Handpiece Holder Wall Mounting Installation USBCam2 User Guide B1051061 Rev. A...
3.1. Operating the Camera Refer to the following sections for instructions on turning the USBCam2 on and off, taking still images from streaming live video ("freeze-frame" capture), and the use of the Auto Advance feature. 3.1.1. Turning the Camera On Before turning on the camera make sure the cable connections are secured.
3.1.3. Pausing and Capturing Images NOTE: The following steps apply to the use of USBCam2 with CDR DICOM software. The operation of the Capture button on the camera handpiece and the buttons on the Video Capture Window (Figure 5) are identical.
Page 26
2. Right-click on the image to open a short context menu. 3. Select Delete. 4. A message will prompt you to confirm that you wish to delete the image. Click Yes to delete the image. (Clicking No cancels the delete operation.) B1051061 Rev. A USBCam2 User Guide...
Page 27
If your current system is not optimized and you need additional details, customers in the United States may contact the Patterson Technology Center at 877-498-6505. Outside the United States, please contact the authorized dealer for Sirona Dental products in your country or region. USBCam2 User Guide B1051061 Rev. A...
(Top: Optimization Disabled; Bottom: Optimization Enabled) 3.2. Using Camera Sheaths Disposable sheaths are provided with each USBCam2 kit as an effective measure for infection control. Use a new sheath for each intra-oral use, and then dispose it of properly. Protective sheaths are single-use devices and must not be reused under any circumstance.
3.3. Using the Camera with CDR DICOM NOTE: Refer to the CDR DICOM User Guide, Schick P/N 1051047, for detailed information on the use and operation of CDR DICOM software. Start CDR DICOM from the Windows Start button or by clicking the shortcut to CDR DICOM for Windows on your desktop.
Page 30
B. The view box that was selected in the main exam flashes green in the small exam. Clicking on a different view box will make that one active instead. B1051061 Rev. A USBCam2 User Guide...
Page 31
• Depress the Green or Amber footpedal if you are using a serial footpedal (Section 3.4). • Press <ALT>and <U> keys at the same time C. To capture another video image, repeat this procedure, starting at Step 7. USBCam2 User Guide B1051061 Rev. A...
3.4. Acquiring Video Images with the Footpedal Serial footpedals (Schick P/N B2501100; PDCO P/N 07-0410100) can be used to control the capture of video images. Refer to the following table for information on using this footpedal to capture video images.
4. Controls 4.1. Controls on the USBCam2 An illustration of the USBCam2 is shown below in Figure 7. For a description of user controls on the camera, refer to Table 3. (1) Camera Lens and Light Source (LEDs) (3) Freeze Frame...
Disposable sheaths are provided with every USBCam2 system. In the U.S., additional sheaths can be ordered from Patterson Dental Supply, Inc. by calling 1-800-328-5536. International customers should contact the authorized international dealer for Sirona Dental products in their country or region.
To avoid cross contamination, follow the cleaning instructions provided by your computer manufacturer and implement them as part of your normal routine for ensuring proper sterilization and disinfectant of tools in your dental practice. USBCam2 User Guide B1051061 Rev. A...
Appendix A. Reference Information A-1. Removal and Replacement Procedures There are no user-serviceable parts in the USBCam2 system. Should you experience problems with the USBCam2, customers in the United States may contact the Patterson Technology Center at 877- 498-6505. Outside the United States, please contact the authorized dealer for Sirona Dental products in your country or region.
Table 5. Guidance and Manufacturer's Declaration - Electromagnetic Emissions PLEASE NOTE: The USBCam2 is intended for use in the electromagnetic environment specified below. The customer or user of the USBCam2 must ensure that it is used in such an environment. Emissions Test...
Table 6. Guidance and Manufacturer's Declaration - Electromagnetic Immunity PLEASE NOTE: The USBCam2 is intended for use in the electromagnetic environment specified below. The customer or user of the USBCam2 must ensure that it is used in such an environment. Immunity Test...
Page 39
If the measured field strength in the location in which the USBCam2 is used exceeds the applicable RF compliance above, the USBCam2 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the USBCam2.
PLEASE NOTE: The USBCam2 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or user of the USBCam2 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the USBCam2 as recommended below, according to the maximum output power of the communications equipment.
Appendix B. Additional Information B-1. Checking DirectX Version and Video Information When installing your USBCam2, you will be prompted to install the latest version of Microsoft's DirectX files on your system (DirectX 9). We strongly recommend that you install these files as earlier versions of DirectX prior to DirectX 8.1 are not compatible with...
There are no user-selectable settings on the Display dialog, which has been omitted.) Image Optimization Indicates whether camera lens barrel correction is enabled. Refer to Section 3.1.6 for details B1051061 Rev. A USBCam2 User Guide...
Table 10. Stream Format Dialog Box Description Item Description Video Format Video Standard: None Frame Rate: 29.970 (may vary) Flip Horizontal: unchecked Color Space / Compression: UYVY Output Size: 640 x 480 Compression (no data) B1051061 Rev. A USBCam2 User Guide...
Appendix C. Troubleshooting Tips C-1. Introduction In the event you experience a problem with the USBCam2, refer to the table of troubleshooting tips found on this page. If the problem persists, please contact your local distributor of Sirona Dental products.
Cleaning and Disinfecting, v Ensure USBCam2 Operates Optimally, iv Items Not Part of the System, iv Deleting Images, 14 Operate the USBCam2 as Directed, iii Disconnect Camera from Cable before Proper PC Workstation Cleaning Methods, v Cleaning/Disinfecting, v Proper System and PC Workstation Installation and...
Page 47
Waste Electrical and Electronic Equipment (WEEE), vii USBCam2 User Guide B1051061 Rev. A...