The unit identification number is not set before the first system power on. The display is set to "00" (flashing).
The enclosure continues to power up even if the unit identification number is not set.
To set the unit identification number:
1. Press and hold the Input switch on the ops panel for a period of five seconds. The left-hand digit flashes.
2. Press and release the Input switch to increment the number until the required digit is reached.
3. Press and hold the Input switch for a period of five seconds. The right-hand digit flashes.
4. Press and release the Input switch to increment the number until the required digit is reached.
5. Press and hold the Input switch for a period of five seconds to finish setting the number. Values of "01"
to "99" are valid.
Once a unit identification number is set, it is stored in the midplane VPD by the Enclosure Management
software and will appear when the enclosure is next powered on. In a situation where the VPD cannot be
read, or where there is no enclosure management (no ESMs, or a single module with management failure) the
enclosure will display "00".
Software/SES
The Enclosure Unit Identification Number may be read and set through CLI and SES.
For both 2U and 5U enclosures, Unit Identification Number can set up. For detailed information, refer to "set_
encl_id" on page 108.

Power Down

To power the enclosure system down, switch off the PCMs or PSUs. Installed in the enclosure by removing
power cords on PCMs or moving the PSU switch to the "Off" position. For PCM, see "Power Cooling
Modules (PCM)" on page 21. For PSU, see "Power Supply Unit (PSU)" on page 22.