Specifications and Reference Data
November 2016
Hygienic Tri Clamp (SC) Seal
Good for use in hygienic applications
Easy installation on Tri-Clover style Tri Clamp connections (1
Conforms to 3-A standard 74-03
Table A-12. SC Hygienic Tri-Clover Style Tri Clamp Seal Ordering Information
H The Standard offering represents the most common options. The starred options (H) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
(1)
Process connection
SC
Tri-Clover style Tri Clamp seal
Process connection size
(2)
3
1½-in.
(2)
5
2-in.
7
3-in.
Maximum working pressure
0
1000 PSI
Isolating diaphragm material
LA00
316L SST
LB00
Alloy C-276
Options
(include with selected model number)
Diaphragm surface finish and polishing
R6
Electropolishing
Remote seal diaphragm surface finish
10 in. (0.25 m) R
RD
15 in. (0.375 m) R
RG
20 in. (0.5 m) R
RH
Surface finish certification
Q16
Surface finish certification for hygienic remote seals
Complete the Rosemount 3051SAL model number by specifying options as needed:
ERS Transmitter options
page 92
1.
Clamp and gasket furnished by user. The maximum working pressure is dependent upon the clamp pressure rating.
2.
Consult factory for calibrated spans lower than 5 psi (345 mbar).
Specifications and Reference Data
diaphragm surface finish
a
diaphragm surface finish
a
diaphragm surface finish
a
1
/
-in. to 3-in.)
2
Upper housing material
316L SST
316L SST
Reference Manual
00809-0100-4804, Rev CB
H
H
H
H
H
H
H
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 3051s

Table of Contents