1. Adjust the staple position by the following service modes.
• Adjustment of front 1-stapling mode
SORTER > ADJUST > INSTP-F1
• Adjustment of rear 1-stapling mode
SORTER > ADJUST > INSTP-R1
• Adjustment of front 2-stapling mode
SORTER > ADJUST > STP-2P
Adjustment range: -50 to 50 (Unit: 0.1mm)
As the value is incremented by 1, the staple position moves by 0.1mm.
+ : Toward rear
- : Toward front
■ Adjusting the Stapler Unit Installation Position
<Use case>
• When the stapler unit is replaced.
• When the staple position in feed direction is displaced in the front/rear 1-stapling mode or 2-stapling mode.
<Procedure of adjustment>
Feed Direction
<Front stapling/Rear stapling>
Feed Direction
<Front stapling/Rear stapling>
+
−
Feed Direction
+
−
< 2-point stapling>
Feed Direction
< 2-point stapling>
82