7.4 Type Tests and Environmental Conditions

Phenomena
ESD
RF field AM
modulated
Fast transient
Surge
RF conducted
Radiated emission
Conducted
emission
Dry heat
Cold
Damp heat
Temperature variation
Vibration
Shock
Isolation
Table 15: Type tests and environmental conditions
Test
Description
EN 61000-4-2
Enclosure contact
Enclosure air
EN 61000-4-3
Enclosure
EN 61000-4-4
Power port
Ethernet port
RS232 port
I/O port
EN 61000-4-5
Ethernet port
Power port
EN 61000-4-6
All ports
EN 55022
Enclosure
EN 55022
DC power ports
Ethernet ports
EN 60068-2-2
Operation
Storage
EN 60068-2-1
Operation
Storage
EN 60068-2-30,
+55 C / +25 C, 12 h – 12 h, 2 cycles
test Db
EN 60068-2-14 Nb
-40 C / +75 C, 3 h / 3 h, 2 cycles, 3 K/min
EN 60068-2-64 ed. 2
Transport. box
DIN rail
direct mounting
EN 60068-2-27 ed. 2
half-sine, 15 g peak, 11 ms, 6 pulses per axis
Ethernet port
30
SmartStart SL302
Test levels
6 kV (crit. A)
8 kV (crit. A)
10 V/m (crit. A)
(80 – 2700 MHz)
3 V/m (crit. A)
(2700 – 6000 MHz)
2 kV (crit. A)
1 kV (crit. A)
1 kV (crit. A)
1 kV (crit. A)
1 kV (crit. A), shielded cab.
0,5 kV (crit. A)
10 V/m (crit. A)
(0,15 – 80 MHz)
Class B
Class B
Class B
+75 C, 40 % rel. humidity,
16 hours
+85 C, 40 % rel. humidity,
16 hours
-40 C, 16 hours
-40 C, 16 hours
3 axis, 1 hour per axis
3 axis, 0.5 hour per axis
3 axis, 8 hours per axis
1.5 kV