Type Tests And Environmental Conditions - Advantech ICR-4453 Hardware Manual

5g industrial router
Hide thumbs Also See for ICR-4453:
Table of Contents

Advertisement

4. Technical Parameters

4.3 Type Tests and Environmental Conditions

Phenomena
ESD
RF field AM
modulated
Fast transient
Surge
RF conducted
Radiated
emis-
sion
Conducted
emission
Dry heat
Cold
Damp heat
Dry heat, cyclic
Dry heat
Thermal
shock/
temp. variation
Degrees of pro-
tection
provided
by enclosures
Vibration, broad-
band random
Shock
ICR-4453 Hardware Manual
Test
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 55032
EN 55032
EN 60068-2-2
EN 60068-2-1
EN 60068-2-78
EN 60068-2-30
EN 60068-2-2
EN 60068-2-14
EN 60529
EN 60068-2-64
EN 60068-2-27
Table 19: Type Tests and Environmental Conditions

4.3 Type Tests and Environmental Conditions

Description
Test levels
Enclosure contact
Enclosure
20 V/m (crit. A)
(80 – 1000 MHz)
10 V/m (crit. A)
(1 – 6 GHz)
Signal ports
Power ports
Ethernet ports
Ethernet ports
Power ports
cab.
All ports
10 V/m (crit. A)
(0.15 – 80 MHz)
Enclosure
Class B
Signal ports
Class B
Power ports
Class B
Ethernet ports
Class B
Test Bb, storage +85 C, operation +75 C
Test Ab, storage -40 C, operation -40 C
95 % rel. humidity (+40 C)
+55 C / +25 C, rel. humidity 95 %, 6 h - 6 h
Test Bb, storage +85 C, operation +75 C
Test Nb, -40 C/+75 C, 3h/3h, 2 cycles, 3 K/min
IP30
Spectrum A.3 cat 1, breakpoints A.6 cat 1
2
50 m/s
, 11 ms, half sine, 10 in each dir.
6 kV (crit. A)
1 kV (crit. A)
2 kV (crit. A)
1 kV (crit. A)
1 kV (crit. A), shielded
1 kV (crit. A)
33

Advertisement

Table of Contents
loading