Type Tests And Environmental Conditions - Advantech ICR-4133 Hardware Manual

Lte advanced industrial router
Table of Contents

Advertisement

4. Technical Parameters

4.3 Type Tests and Environmental Conditions

Phenomena
ESD
RF field AM
modulated
Fast transient
Surge
RF conducted
Radiated
emis-
sion
Conducted
emission
Dry heat
Cold
Damp heat
Dry heat, cyclic
Dry heat
Thermal
shock/
temp. variation
Degrees of pro-
tection
provided
by enclosures
Vibration, broad-
band random
Shock
ICR-4133 Hardware Manual
Test
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 55032
EN 55032
EN 60068-2-2
EN 60068-2-1
EN 60068-2-78
EN 60068-2-30
EN 60068-2-2
EN 60068-2-14
EN 60529
EN 60068-2-64
EN 60068-2-27
Table 12: Type Tests and Environmental Conditions

4.3 Type Tests and Environmental Conditions

Description
Test levels
Enclosure contact
Enclosure
20 V/m (crit. A)
(80 – 1000 MHz)
10 V/m (crit. A)
(1 – 6 GHz)
Signal ports
Power ports
Ethernet ports
Ethernet ports
Power ports
cab.
All ports
10 V/m (crit. A)
(0.15 – 80 MHz)
Enclosure
Class B
Signal ports
Class B
Power ports
Class B
Ethernet ports
Class B
Test Bb, storage +85 C, operation +75 C
Test Ab, storage -40 C, operation -40 C
95 % rel. humidity (+40 C)
+55 C / +25 C, rel. humidity 95 %, 12 h - 12 h
Test Bb, storage +85 C, operation +75 C
Test Nb, -40 C/+75 C, 3h/3h, 2 cycles, 3 K/min
IP30
Spectrum A.3 cat 1, breakpoints A.6 cat 1
2
50 m/s
, 11 ms, half sine, 10 in each dir.
6 kV (crit. A)
1 kV (crit. A)
2 kV (crit. A)
1 kV (crit. A)
1 kV (crit. A), shielded
1 kV (crit. A)
26

Advertisement

Table of Contents
loading

Table of Contents