4. Technical Specifications

4.3 Type Tests and Environmental Conditions

Phenomena
ESD
RF field AM
modulated
Fast transient
Surge
RF conducted
Radiated emission
Conducted
emission
Dry heat
Cold
Variation of
temperature
Dry heat, cyclic
ICR-2031 Hardware Manual
Test
Description
EN 61000-4-2
Enclosure
EN 61000-4-3
Enclosure
EN 61000-4-4
DC port
ETH - FTP
Digital input
Digital output
EN 61000-4-5
ETH
EN 61000-4-6
DC port
ETH
I/O ports
EN 55032
Enclosure
EN 55032
DC power port
Ethernet ports
EN 60068-2-2
Operating
Storage
EN 60068-2-1
Operating
Storage
EN 60068-2-14
Test Nb, -40 C / +75 C, 3h/3h, 2 cycles, 3 K/min
EN 60068-2-30
+55 C / +25 C, rel. humidity 95 %, 6 h-6 h
Table 12: Type Tests and Environmental Conditions

4.3 Type Tests and Environmental Conditions

Test levels
CD
6 kV, L3
20 V/m, 80 MHz-1 GHz, LX
10 V/m, 1 GHz-6 GHz, L3
1 kV, 5/50 Tr/Th ns, 100 kHz, L2
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
1 kV, 5/50 Tr/Th ns, 100 kHz, L3
1 kV, 1.2/50(8/20) Tr/Th us, L2
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
10 V, 0.15-80 MHz, 80%AM(1kHz), L3
Class B, 30 MHz-1 GHz, 1 GHz-6 GHz
Class B, 150 kHz-30 MHz
Class B, 150 kHz-30 MHz
Test Bb, storage +75 C
Test Bd, operation +85 C
Test Ab, storage -40 C
Test Ad, operation -40 C