Type Tests And Environmental Conditions - Advantech SmartStart SL305 Hardware Manual

Industrial cellular router
Hide thumbs Also See for SmartStart SL305:
Table of Contents

Advertisement

5. Technical Parameters

5.4 Type Tests and Environmental Conditions

Phenomena
ESD
Radiated RF immu-
nity
Fast transient
Surge
RF conducted
Voltage dips, interrup-
tions
Dry heat
Cold
Damp heat
Temperature variation
Vibration
Shock
Isolation
SmartStart SL305 Hardware Manual
Test
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
EN 60068-2-2
EN 60068-2-1
EN 60068-2-30,
test Db
EN 60068-2-14 Nb
EN 60068-2-64 ed. 2
EN 60068-2-27 ed. 2
Table 15: Type tests and environmental conditions
5.4 Type Tests and Environmental Conditions
Description
Test levels
Enclosure
AC port
Enclosure
DC port
Enclosure
10 V/m, 80mHz - 6 GHz
Power port
Ethernet port
RS485 port
I/O port
AC-DC
Ethernet port
1 kV (crit. A), shielded cab.
Power port
AC-DC
All ports
10 V (crit. A)
(0,15 – 80 MHz)
AC-DC
10 V (crit. A)
AC-DC
Operation
+75 C, 40 % rel. humidity,
16 hours
Storage
+85 C, 40 % rel. humidity,
16 hours
Operation
-40 C, 16 hours
Storage
-40 C, 16 hours
+55 C / +25 C, 6 h – 6 h, 2 cycles
-40 C / +75 C, 3 h / 3 h, 2 cycles, 3 K/min
Transport. box
3 axis, 1 hour per axis
DIN rail
3 axis, 0.5 hour per axis
direct mounting
3 axis, 8 hours per axis
half-sine, 15 g peak, 11 ms, 6 pulses per axis
Ethernet port
1.5 kV
6 kV (crit. A)
8 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
0,5 kV (crit. A)
1 kV (crit. A) L-L
26

Advertisement

Table of Contents
loading

Table of Contents