Fault Code/Name
oPE07
A contradictory setting is assigned to
multi-function analog inputs.
Analog Setup Alm
oPE08
A function has been set that cannot be
used in the motor control method
Mode Setting Alm
selected.
oPE10
The following setting errors have
occurred where:
V/F Setup Alm
oPE16
Energy Savings Constants Error
EnrgSavSetup Alm
Parameter Setting Error:
oPE18
A configuration relating to load cell
inputs is incorrect. This is a non-standard
ParamSetting Alm
feature, contact Magnetek for further
assistance.
oPE20
The encoder signal frequency is too high.
PPR setting Alm
oPE21
Elevator parameters are not set correctly.
Start Setup Alm
The external operator has been
disconnected from the drive.
oPr
Note: An oPr fault will occur
Oper Disconnect
Operator Con Alm
• Output is interrupted when the operator
is disconnected.
oS
The motor speed feedback exceeded the
Overspeed Flt
Overspd Det Lvl (A1).
Overspeed Alm
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Description
when all of the
following conditions
are true:
Causes and Solutions
At least two analog input terminals are set to the same function.
Attempted to use a function that is not valid for the selected control mode.
Note: Use oPE Flt Parameter (F2) to find which parameter is
causing the oPE08 to be declared. Other errors are given
precedence over oPE08 when multiple errors occur
simultaneously.
Incorrect selection for Control Method (U8)
• Check the selected control mode in the U8 sub-menu.
Correct the settings for VF pattern in the A5 menu.
Energy saving coefficients are out of the allowable range.
Multiple parameters relating to load cell inputs have the same setting. This is
a non-standard feature, contact Magnetek for assistance.
With the entered Encoder Pulses (A1), Rated Motor Freq (A5) and Number
Of Poles (A5), the calculation encoder signal frequency exceeds 50 kHz (with
PG-F3 option) or 20 kHz (with PG-E3 option).
• Set Encoder Pulses (A1) to the correct encoder resolution.
• Reduce the maximum output frequency of the drive in parameter Rated
Motor Freq (A5) so the encoder signal frequency at maximum speed is
lower than 50 kHz.
The DC Brk Time Stop (A1) is set to a value lower than the Brake Close
Delay A1.
• Correct parameter settings.
External operator is not properly connected to the drive.
• Check the connection between the operator and the drive.
• Replace the cable if damaged.
• Turn off the drive input power and disconnect the operator. Then reconnect
the operator and turn the drive input power back on.
Overshoot is occurring.
• If using a closed loop vector mode, increase Inertia (A1).
Inappropriate parameter settings.
• Check the setting for the Oversp Det Lvl (A1) and Overspd Det Time (A1).
7 Troubleshooting