C2 Parameter Name
Logic Input S1
Logic Input S2
Logic Input S3
Logic Input S4
Logic Input S5
Logic Input S6
Logic Input S7
Logic Input S8
C2 Parameter
Choice
Brake Feedback NC
Brake Feedback Normally Closed
Brake Feedback NO
Brake Feedback Normally Open
Comm Test Mode
Serial Comm Test Mode
Contact Cnfm NC
Contactor Confirmation Normally Closed
Contact Cnfm NO
Contactor Confirmation Normally Open
DL Dist Correctn
Stop Distance Correction Input
Drive Enable
Drive Enable
BaseBlock NC
Base Block Normally Closed
BaseBlock NO
Base Block Normally Closed
Fast-Stop NO
Fast Stop Normally Open
Fast-Stop NC
Fast Stop Normally Closed
Fault Reset
Fault Reset
Insp Operation
Inspection Operation
Intermed Speed
Intermediate Speed
Jog Freq Ref
Jog Frequency Reference
Leveling Speed
Leveling Speed
Mains Dip Enable
Mains Dip Enable
Multi-Step Ref 1
Multi-Step input 1
Multi-Step Ref 2
Multi-Step input 2
Multi-Step Ref 3
Multi-Step input 3
Multi-Step Ref 4
Multi-Step input 4
Normally Closed External Fault (always detect,
NC Ext Fault 1
ramp to stop)
Normally Closed External Fault (always detect,
NC Ext Fault 2
cost to stop)
Normally Closed External Fault (always detect,
NC Ext Fault 3
fast stop)
Normally Closed External Fault (always detect,
NC Ext Fault 4
alarm only)
Normally Closed External Fault (during run,
NC Ext Fault 5
ramp to stop)
Normally Closed External Fault (during run,
NC Ext Fault 6
cost to stop)
Normally Closed External Fault (during run, fast
NC Ext Fault 7
stop)
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Table 7 Logic Inputs C2 Submenu
Logic Input 1 on terminal S1
Logic Input 2 on terminal S2
Logic Input 3 on terminal S3
Logic Input 4 on terminal S4
Logic Input 5 on terminal S5
Logic Input 6 on terminal S6
Logic Input 7 on terminal S7
Logic Input 8 on terminal S8
Table 8 Logic Input Choices
Description
Description
C2 Parameter
Choice
Normally Closed External Fault (during run,
NC Ext Fault 8
alarm only)
Normally Open External Fault (always detect,
NO Ext Fault 1
ramp to stop)
Normally Open External Fault (always detect,
NO Ext Fault 2
cost to stop)
Normally Open External Fault (always detect,
NO Ext Fault 3
fast stop)
Normally Open External Fault (always detect,
NO Ext Fault 4
alarm only)
Normally Open External Fault (during run, ramp
NO Ext Fault 5
to stop)
Normally Open External Fault (during run, cost
NO Ext Fault 6
to stop)
Normally Open External Fault (during run, fast
NO Ext Fault 7
stop)
Normally Open External Fault (during run,
NO Ext Fault 8
alarm only)
Nominal Speed
Nominal Speed Input
Not Used
Input Not Used
Pre-Torque Latch
Pre-Torque Latch Input
Re-Lvling Speed
Re-Leveling Speed Input
Rescue Operation
Rescue Operation Input
Run Down
Run Down Input
Run Up
Run Up Input
Run
Run Input
S-curve Select 0
S-curve Select 0 Input
S-curve Select 1
S-curve Select 1 Input
Ser2 Insp Ena
Ser2 Insp Enable Input
Speed Limit Down
Speed Limit Down
Speed Limit Up
Speed Limit Up
Timer function
Timer function
Up/Down
Up/Down Input
5 Programming
Default
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Description
23