Magnetek Elevator HPV1000 AC Technical Manual page 19

Ac elevator drive
Hide thumbs Also See for HPV1000 AC:
Table of Contents

Advertisement

A1 Parameter Name
Contactor DO Dly
Load Sense Time
Load Sense Speed
Rescue Trq Limit
UPS Power Rating
DCVoltLvl@Rescue
PS ReuctnDetLvl
FieldForce Limit
,
<2>
<3>
Mtr Mag Flt Time
Ser1 Spd Filter
Spd Input Filter
,
<3>
<4>
Mains Dip Speed
Ser2 Res CrpTime
Ser2 Res Crp Spd
Ser2 Fault Tol
Ser2 Insp Spd
<1> Parameter accessible in V/f control mode
<2> Parameter accessible in Open Loop Vector control mode
<3> Parameter accessible in Closed Loop Vector control mode
<4> Parameter accessible in PM Closed Loop Vector control mode
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Description
Determines the delay time between shutting off the output of the drive
and resetting the contactor control output (C3 'Close Contact') in order
to release the motor contactor after a run has finished.
Sets the time to perform Light Load Direction Search.
Sets the speed reference (percent of contract car speed) to use during
Light Load Direction Search.
Sets the maximum motor torque when the drive is in Rescue
Operation Mode.
Sets the capacity of the UPS used when the drive is in Rescue
Operation Mode.
Sets the DC bus voltage the drive should expect when the drive is in
Rescue Operation Mode.
Determines at which level of backup power supply deterioration a
PF5 fault is triggered in Rescue Operation.
Sets the maximum limit of the excitation current command during
magnetic field forcing. A setting of 100% is equal to motor no-load
current. Disabled only during DC injection Braking.
Sets a delay time to let the drive produce no-load current in the
induction motors before the Starting Current Fault is declared.
Applies a filter when Spd Command SRC (C1) is set to Serial and
Serial Mode (C1) is Mode 1.
A setting of 0.00 s disables this feature.
Filter applied to the speed feedback and commanded speed before the
E-Reg Process
This parameter sets the percentage of contract speed for the speed to
be reduced when the drive goes into 'low voltage' mode. The Mains
Dip function is enabled by the Mains Dip Enable (MAINS DIP
ENA(C1)) parameter. When the drive goes into 'low voltage' mode, it
reduces the speed by the percentage defined by this parameter. 'Low
voltage' mode is defined as when the drive declares a UV alarm,
which is defined by the Input line-to-line voltage (INPUT L-L
VOLTS(A4)) parameter and the Undervoltage.
When in Serial Mode 2 and SER2 FLT MODE (C1)=rescue, this
parameter defines the maximum time the drive will continue to run at
rescue creep speed (defined by SER2 RS CRP SPD (A1) parameter)
when reacting to a serial fault. The time is defined as the time running
at creep speed. It does not include the time it takes to decelerate to
creep speed.
When in Serial Mode 2 and SER2 FLT MODE (C1)=rescue, this
parameter defines the creep speed that will be used in the "rescue
mode".
When in Serial Mode 2, this parameter defines the maximum time that
may elapse between valid run time messages while in serial run mode
before a serial fault is declared.
When in Serial Mode 2, this parameter defines the inspection speed to
be used. To run in inspection speed via serial mode 2 requires that the
run command for inspection speed come from two sources, a
command sent in a serial message and via hardware as a logic input
defined as "SER2 INSP ENA".
5 Programming
Units
Default
Sec
0.10
Sec
1.0
5.00
,
<1>
<2>
%
10.00
<4>
%
100
kVA
0
V
0
%
80
%
,
400
,
<2>
<3>
<2>
ms
0200
Sec
0.00
ms
,
002
,
<3>
<4>
<3>
%
25.00
Sec
180
m/s
0.00
Sec
0.50
m/s
0.00
,
<3>
<3>
<4>
17