Magnetek Elevator HPV1000 AC Technical Manual page 26

Ac elevator drive
Hide thumbs Also See for HPV1000 AC:
Table of Contents

Advertisement

5 Programming
C3 Parameter Name
Logic output P1
Logic output P2
Relay M1-M2
Relay M3-M4
Relay M5-M6
C3 Choice
Auto Brake Output (uses encoder feedback to
Auto Brake
ensure motor is stationary before setting)
BaseBlock NO
Base Block output Normally Open
BaseBlock NC
Base Block output Normally Closed
Brake Pick Output (uses run signaling/timers to set
Brake Pick
the brake)
Close Contact
Motor Contactor output
DBR Trans Flt
Dynamic Braking Transistor Fault
DC Bus Undervolt DC Bus Undervolt Fault
Door Zone
Door Zone Output
Drive Ready
Drive Ready to Run
Dur Flt Restart
Drive fault being reset
During Run 1
Output closes when the drive is outputting a voltage
Output closes when the drive is outputting a
During Run 2
frequency
Fan Alarm
Internal cooling fan alarm
Fault
Drive in a faulted state
Input Ph Loss
Input Phase Loss detected
LightLoadDetStat Light Load Direction Detection Status
LightLoadDirect
Light Load Direction
Maintenance
Drive requires maintenance
Minor Fault
A Minor fault is active
Motor Overload
Motor Overload fault active
Not Used
Output not used
Overheat Alarm
Motor or drive over temperature alarm active
Ovld Shdwn Alm
Overload shutdown alarm active
Regenerating
,
<3>
Drive is running and regenerating (not motoring)
<4>
Reset Cmd Active Fault Reset input active
Reverse Dir
Lift traveling in reverse direction (down)
SafeDisable Stat
Safe Disable Status
Spd Detection 3
Speed Detection 3
Spd Detection 4
Speed Detection 4
Spd Ref Release
Speed Reference Release active
Spd Reg Release
Speed Regulator Release active
SRef/Out Agr 1
Speed Reference Agree 1
SRef/Out Agr 2
Speed Reference Agree 2
SRef/Set Agr 1
Speed User Set Agree 1
SRef/Set Agr 2
Speed User Set Agree 2
Speed Dev Low
Speed Deviation low active
,
<3>
<4>
Torque Detect 1
Torque Detect 1
Torque Detect 2
Torque Detect 2
Torque Limit
Drive in Torque Limit
,
,
<2>
<3>
<4>
Zero Speed
Zero speed output
! BaseBlock NC
Base Block output Normally Open (Inverse)
24
Table 9 C3 Logic Outputs
Terminal P1 - C1 Function Selection (photocoupler)
Terminal P2 - C2 Function Selection (photocoupler)
Terminal M1 - M2 Function Selection (relay)
Terminal M3 - M4 Function Selection (relay)
Terminal M5 - M6 Function Selection (relay)
Table 10 Logic Output Choices
Description
Description
C3 Choice
! BaseBlock NO
Base Block output Normally Closed (Inverse)
Brake Pick Output (uses run signaling/timers to set
! Brake Pick
the brake) (Inverse)
! Close Contact
Motor Contactor output (Inverse)
! Drive Ready
Drive Ready to Run (Inverse)
! DBR Trans Flt
Dynamic Braking Transistor Fault (Inverse)
! DCBus Undervlt DC Bus Undervolt Fault (Inverse)
! Door Zone
Door Zone Output (Inverse)
Output closes when the drive is outputting a
! During Run 1
voltage (Inverse)
Output closes when the drive is outputting a
! During Run 2
frequency (Inverse)
! Fan Alarm
Internal cooling fan alarm (Inverse)
! Fault
Drive in a faulted state (Inverse)
! Input PH Loss
Input Phase Loss detected (Inverse)
! LiteLoadDetSta
Light Load Direction Detection Status (Inverse)
! LiteLoadDirect
Light Load Direction (Inverse)
! Maintenance
Drive requires maintenance (Inverse)
! Minor Fault
A Minor fault is active (Inverse)
! Motor Overload
Motor Overload fault active (Inverse)
Motor or drive over temperature alarm active
! Overheat Alarm
(Inverse)
! Ovld Shdwn Alm Overload shutdown alarm active (Inverse)
! Regenerating
Drive is running and regenerating (Inverse)
,
<3>
<4>
! ResetCmd Activ Fault Reset input active (Inverse)
! Restart Enable
Output active unless drive fault auto reset occurring
! Reverse Dir
Lift traveling in reverse direction (down) (Inverse)
! SafeDisablStat
Safe Disable Status
! Spd Ref Rls
Speed Reference Release active (Inverse)
! Spd Reg Rls
Speed Regulator Release active (Inverse)
! Speed Dev Low
Speed Deviation low active (Inverse)
,
<3>
<4>
! SRef/Out Agr 1
Speed Reference Agree 1 (Inverse)
! SRef/Out Agr 2
Speed Reference Agree 2 (Inverse)
! SRef/Set Agr 1
Speed User Set Agree 1 (Inverse)
! SRef/Set Agr 2
Speed User Set Agree 2 (Inverse)
! Torque Limit
Drive in Torque Limit (Inverse)
,
,
<2>
<3>
<4>
! Trq Det 1 N.O.
Torque Detect 1 (Inverse)
! Trq Det 2 N.O.
Torque Detect 2 (Inverse)
! Zero Speed
Zero speed output (Inverse)
<2> Parameter accessible in Open Loop Vector control mode
<3> Parameter accessible in Closed Loop Vector control mode
<4> Parameter accessible in PM Closed Loop Vector control mode
<5> Default is dependent on drive model number
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Default
Not Used
Not Used
Not Used
Not Used
Not Used
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents