Display Menu Parameters - Magnetek Elevator HPV1000 AC Technical Manual

Ac elevator drive
Hide thumbs Also See for HPV1000 AC:
Table of Contents

Advertisement

Display Menu Parameters

D1 Parameter Name
Speed Command
Speed Reference
Speed Feedback
,
,
<2>
<3>
<4>
Speed Error
,
<3>
<4>
Encoder Speed
Logic Outputs
Logic Inputs
SrlBytesReceived
SerialBytesSent
Drive Status
Analog A1 Level
Analog A2 Level
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Table 15 ELEVATOR DATA D1 Submenu
Speed Command:
Displays the commanded speed from the controller.
Speed Reference:
Displays the drive speed reference.
Speed Feedback:
Displays the speed feedback measured from the motor.
Speed Reference-Speed Feedback:
Shows the amount of speed error seen by the encoder.
Encoder Speed:
Displays the measured speed from the encoder.
Output Terminal Status:
Displays the output terminal status.
00000000
Terminal M1-M2
Terminal M3-M4
Terminal M5-M6
Terminal P1-C1
Terminal P2-C2
N/A
Terminal MA-MB-MC
Input Terminal Status:
Displays the input terminal status.
00000000
Terminal S1
Terminal S2
Terminal S3
Terminal S4
Terminal S5
Terminal S6
Terminal S7
Terminal S8
Serial Bytes Received:
Number of valid HPV Mode 1 Runtime bytes the drive received after a power up.
Note: The value rolls over after 65535.
Serial Bytes Received:
Number of valid HPV Mode 1 response bytes the drive received after a power up.
Note: The value rolls over after 65535.
Internal Control Status:
Displays the input terminal status.
00000000
During run
During zero-speed
During down direction
During fault reset signal input
During speed agree
During ready
During alarm detection
During fault detect
Terminal A1 Level:
Displays the voltage input to terminal A1.
Terminal A2 Level:
Displays the voltage input to terminal A2.
Description
5 Programming
Units
m/s
m/s
%
,
<3>
<4>
m/s
,
,
<2>
<3>
<4>
RPM
1 = on, 0 = off
1 = on, 0 = off
number of byte
number of byte
1 = on; 0 = off
%
%
29

Hide quick links:

Advertisement

Table of Contents
loading