5 Programming
D1 Parameter Name
Torque Comp
,
<3>
<4>
Measured PPR
Z-Edge Count
Rx Com Status
<2> Parameter accessible in Open Loop Vector control mode
<3> Parameter accessible in Closed Loop Vector control mode
<4> Parameter accessible in PM Closed Loop Vector control mode
<5> Default is dependent on drive model number
30
Torque Compensation:
Torque Compensation Input value. Used for either Pre-Torque or Feed Forward
operation, depending on Trq Comp Type (C1).
Measured Pulses Per Revolution:
Only for Incremental PM, this displays the measured encoder pulses for one
revolution of the motor (determined by the Z index).
Z-Edge Count:
Only for Incremental PM, this displays the amount of motor revolution (determined
by index pulses from the Z index channel).
Rx Com Status
Serial communication status display
Description
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Units
%
,
<3>
<4>
PPR
-
Hex