D2 Parameter Name
DC Bus Voltage:
DC Bus Voltage
Displays the measured DC bus voltage.
Output Current:
Motor Current
Displays the measured output current to the motor.
Output Voltage:
Motor Voltage
Displays the output voltage to the motor.
Motor Freq
Displays the output frequency to the motor.
Torque
Torque Reference:
Reference
,
,
Displays the internal torque reference.
<2>
<3>
<4>
Output Kilowatts:
Power Output
Displays the output power (this value is calculated internally).
Motor Overload Level:
Motor Overload
Shows the value of the motor overload detection accumulator. 100% is equal to the
Motor Overload detection level.
Drive Overload Level:
Drive Overload
Displays the level of the drive overload detection level. A value of 100% is equal to the
Drive Overload detection level
Current Peak Hold:
Current PeakHold
Displays the highest current value that occurred during a ride.
Heatsink Temperature:
Heatsink Temp
Displays the heatsink temperature.
Drive Elapsed Time:
Displays the cumulative operation time of the drive. The value for the cumulative
Drv Elapsed Time
<6>
operation time counter can be reset. Contact Magnetek for details. The maximum
number displayed is 99999, after which the value is reset to 0.
Fan Elapsed Time:
Displays the cumulative operation time of the cooling fan. This value can be reset.
Fan Elapsed Time
<6>
Contact Magnetek for details. This value will reset to 0 and start counting again after
reaching 99999.
Fan Life Monitor:
Displays main cooling fan usage time in as a percentage of its expected performance
Fan Life Mon
<6>
life. This value can be reset. Contact Magnetek for details. The fan should be replaced
when this monitor reaches 90%.
Capacitor Life Monitor:
Displays main circuit capacitor usage time in as a percentage of their expected
Cap Life Mon
<6>
performance life. The capacitors should be replaced when this monitor reaches 90%.
This value can be reset. Contact Magnetek for details.
IGBT Life Monitor:
Displays IGBT usage time as a percentage of the expected performance life. The IGBTs
IGBT Life Mon
<6>
should be replaced when this monitor reaches 90%. This value can be reset. Contact
Magnetek for details.
Maximum Current at Acceleration:
Max Accel Amps
Shows the maximum current that occurred during acceleration.
Maximum Current at Deceleration:
Max Decel Amps
Shows the maximum current that occurred during deceleration.
Maximum Current at Run:
Max Run Amps
Shows the maximum current that occurred during ride at top speed.
Slip Compensation Value:
Slip Comp Value
,
<1>
<2>
Shows the slip compensation value.
Flux Position:
Flux Position
Displays the angular position of the PM flux position. This number is dependent on the
setting of Enc Z-Pulse Offs (A5).
Pulse Generator Counter:
PG Counter
Displays the number of pulses for speed detection.
<1> Parameter accessible in V/f control mode
<2> Parameter accessible in Open Loop Vector control mode
<3> Parameter accessible in Closed Loop Vector control mode
<4> Parameter accessible in PM Closed Loop Vector control mode
<6> Only available in Alternate Navigation menu. Contact Magnetek for details.
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Table 16 POWER DATA D2 Submenu
Description
5 Programming
Units
VDC
A
VAC
Hz
% of rated torque
,
,
<2>
<3>
<4>
kW
% of motor amp rating
% drive amp rating
A
C
Hours
Hours
% of expected operation time
% of expected operation time
% of expected operation time
A
A
A
%
,
<1>
<2>
Deg
PPR
31