Magnetek Elevator HPV1000 AC Technical Manual page 28

Ac elevator drive
Hide thumbs Also See for HPV1000 AC:
Table of Contents

Advertisement

5 Programming
C5 Parameter Name
Analog A1 Select
Analog A1 Gain
Analog A1 Bias
Analog A1 Offset
Analog A1 Level
Analog A2 Select
Analog A2 Gain
Analog A2 Bias
Analog A2 Offset
Analog A2 Level
Analog In Filter
C5 Choice
Motor PTC
Not Used
Speed Command
Pre-Torque
26
Table 13 C5 Analog Inputs
Analouge Input A1 Function Select
Sets the gain level of the input value when 10 V is applied at terminal A1.
Sets the level of the input value when 0 V is applied at terminal A1
Applies an offset to analog input A1. Can be used for zero adjustment of the analog input.
Sets the required working range of analog input A1
Analouge Input A2 Function Select
Sets the gain level of the input value when 10 V is applied at terminal A2.
Sets the level of the input value when 0 V is applied at terminal A2.
Applies an offset to analog input A2. Can be used for zero adjustment of the analog input.
Sets the required working range of analog input A2
Sets a primary delay filter time constant for terminals A1 and A2. Used for noise filtering.
Table 14 Analog Input Choices
Motor Thermistor Input
Declares a Motor OH Alarm at 1.18v
Declares a Motor OH Fault at 2.293v
Input disabled
Used as the primary external speed reference when the drives speed profile is dictated by an
external speed profile generator within the control system.
Load cell input when Trq Comp Type (C1) is configured to Pre-Torque or Torque Feed Forward
when Trq Comp Type (C1) is configured to Feed Forward.
Description
Description
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Default
Not Used
100.0
0.0
0000
-10 ~ +10VDC
Not Used
100.0
0.0
0000
-10 ~ +10VDC
0.03