Magnetek Elevator HPV1000 AC Technical Manual page 35

Ac elevator drive
Hide thumbs Also See for HPV1000 AC:
Table of Contents

Advertisement

The drive will then automatically populate the following parameters in the A1 and A5 menus:
• Rated Mtr Power (A5)
• Rated Mtr Volts (A5)
• Rated Motor Freq (A5)
• Rated Motor Curr (A5)
• Number of Poles (A5)
• Motor Rated Slip (A5) - calculated from autotune
• No-Load Current (A5)
• Leak Inductance (A5) - calculated from autotune
• Term Resistance (A5) - calculated from autotune
• Min Voltage (A5) - calculated from autotune
• Min Frequency (A5) - calculated from autotune
• Mid Voltage (A5) - calculated from autotune
• Mid Frequency (A5) - calculated from autotune
Low-Speed Inspection Mode
Run the drive in low-speed inspection mode and verify proper hoistway direction can be reversed with the MOTOR
ROTATION (C1) parameter.
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
6 Installation Startup and Autotune Guides
33

Hide quick links:

Advertisement

Table of Contents
loading