7 Troubleshooting
Fault Code/Name
oFA05, oFA06
CNA Card A/D Flt
CNA Card Com Flt
oFA10, oFA11
CNA Card Ram Flt
CNA Card Ope Flt
oFA12 to oFA17
Drv CRC Flt
Drv Frame Flt
Drv Abort Flt
CNA CRC Flt
CNA Frame Flt
Option card error occurred at option port
CNA Abort Flt
CN5-A.
oFA30 to oFA43
Com ID Flt
Type Code Flt
Sum Chk Flt
Opt TimeOver Flt
Memobus Time Flt
Inv Time Flt 1
Cl Chk Flt
Inv Time Flt 2
Ctrl Ref Flt
Inv Time Flt 3
CtrlResSel Flt 1
Inv Time Flt 4
CtrlResSel Flt 2
Inv Time Flt 5
Option Card Fault at Option Port CN5-B:
oFb00
Option compatibility error.
oFb01
Option not properly connected.
CNB Connect Flt
oFb02
Same type of option card already
connected.
CNBDuplicate Flt
54
Description
Causes and Solutions
Option card or hardware is damaged.
• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive.
Contact Magnetek for instructions on replacing the control board.
The option card installed into port CN5-B is incompatible with the drive.
• Make sure the drive supports the option card to be installed. Contact
Magnetek for assistance.
A communication option card has been installed in option port CN5-B.
• Communication option cards are only supported by option port CN5-A. It
is not possible to install more than one comm. option.
PG-F3 is connected to option port CN5-B.
• PG-F3 is only supported by option port CN5-C. Place PG-F3 on the top
option port.
The option board connection to port CN5-B is faulty.
• Turn off the power and reconnect the option card.
• Check if the option card is properly plugged into the option port. Make sure
the card is fixed properly.
• Try to use the card in another option port (in case of a PG option use
CN5-C). If the option cards work in the other port, replace the drive
because port CN5-B is damaged. If the error persists (oFA01 or oFC01
occur), replace the option board.
An option card of the same type is already installed in option port CN5-A.
• Except for PG options, each option card type can only be installed once.
Make sure only one type of option card is connected.
An input option card is already installed in option port CN5-A.
• Install a comm. option, a digital input option, or an analog input option.
The same type of card cannot be installed twice.