5 Programming
A2 Parameter Name
Accel Rate 0
Decel Rate 0
Accel Jerk In 0
Accel Jerk Out 0
Decel Jerk In 0
Decel Jerk Out 0
Accel Rate 1
Decel Rate 1
Accel Jerk In 1
Accel Jerk Out 1
Decel Jerk In 1
Decel Jerk Out 1
Accel Rate 2
Decel Rate 2
Accel Jerk In 2
Accel Jerk Out 2
Decel Jerk In 2
Decel Jerk Out 2
Accel Rate 3
Decel Rate 3
Accel Jerk In 3
Accel Jerk Out 3
Decel Jerk In 3
Decel Jerk Out 3
Fast Stop Time
18
Table 2 S-Curves A2 Submenu
Description
Acceleration Rate Limit
Deceleration Rate Limit
Rate of increase of acceleration, up to ACCEL RATE, when
increasing elevator speed
Rate of decrease of acceleration to zero when approaching contract
elevator speed
Rate of increase of deceleration, up to DECEL RATE, when
decreasing elevator speed
Rate of decrease of deceleration to zero when slowing the elevator to
zero or level speed
Acceleration Rate Limit
Deceleration Rate Limit
Rate of increase of acceleration, up to ACCEL RATE, when
increasing elevator speed
Rate of decrease of acceleration to zero when approaching contract
elevator speed
Rate of increase of deceleration, up to DECEL RATE, when
decreasing elevator speed
Rate of decrease of deceleration to zero when slowing the elevator to
zero or level speed
Acceleration Rate Limit
Deceleration Rate Limit
Rate of increase of acceleration, up to ACCEL RATE, when
increasing elevator speed
Rate of decrease of acceleration to zero when approaching contract
elevator speed
Rate of increase of deceleration, up to DECEL RATE, when
decreasing elevator speed
Rate of decrease of deceleration to zero when slowing the elevator to
zero or level speed
Acceleration Rate Limit
Deceleration Rate Limit
Rate of increase of acceleration, up to ACCEL RATE, when
increasing elevator speed
Rate of decrease of acceleration to zero when approaching contract
elevator speed
Rate of increase of deceleration, up to DECEL RATE, when
decreasing elevator speed
Rate of decrease of deceleration to zero when slowing the elevator to
zero or level speed
Used when a Fast Stop is invoked.
Units
m/s
2
m/s
2
m/s
3
m/s
3
m/s
3
m/s
3
m/s
2
m/s
2
m/s
3
m/s
3
m/s
3
m/s
3
m/s
2
m/s
2
m/s
3
m/s
3
m/s
3
m/s
3
m/s
2
m/s
2
m/s
3
m/s
3
m/s
3
m/s
3
m/s
2
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Default
0.80
0.80
0.60
0.60
0.60
0.60
0.80
0.80
0.60
0.60
0.60
0.60
0.80
0.80
0.60
0.60
0.60
0.60
0.80
0.80
0.60
0.60
0.60
0.60
2.0