Magnetek Elevator HPV1000 AC Technical Manual page 24

Ac elevator drive
Hide thumbs Also See for HPV1000 AC:
Table of Contents

Advertisement

5 Programming
C1 Parameter Name
Ser2 Fault Mode
Trq Comp Cmd Src
,
<3>
<4>
Trq Comp Latch
,
<3>
<4>
Trq Comp Type
,
<3>
<4>
Mtr Overload Act
Field Force Sel
,
<2>
<3>
Restart Sel
Out Ph Loss Det
DB Tr Protection
Autotune Cont On
Power Supply Sel
Auto Fc Reduce
OH Pre-Alarm Sel
Inp Ph Loss Det
PPT Select
Mains Dip Enable
Output V Lim Sel
,
,
<2>
<3>
<4>
Fan Selection
Inspection PWM
Rescue PWM
<2> Parameter accessible in Open Loop Vector control mode
<3> Parameter accessible in Closed Loop Vector control mode
<4> Parameter accessible in PM Closed Loop Vector control mode
<5> Default is dependent on drive model number
22
Description
Defines how the drive will react if serial communication is
lost (when using serial mode 2 only).
Immediate - the lift will crash stop immediately.
Rescue - the lift will continue at SER2 Res Crp Spd until
either the enable signal is removed or Ser2 ResCrpTime
elapses.
Run Remove - the drive will behave in the same way as if a
run command is removed as defined by other sequencing
parameters (stopping mode, etc.).
Selects the source for the Torque Compensation Command if
used.
If Torque Compensation is used, this parameter selects
whether the values is latched on run command.
Selects which Torque Compensation method is used
Determines which action the drive takes when a Motor
Overload has been detected.
Determines if Field Forcing is in operation
Determines if the fault output is active when a reset is
attempted
Defines the output (motor) phase loss detection method
Defines if the internal DBR protection is active (can be
disabled when using a regen unit or external brake module)
Determines the state of the motor contactor output during
Auto-Tuning.
Selects the backup power supply method.
If enabled, Torque Boost increases the output current limit
while decreasing the carrier frequency when required
Defines the operation in the event of an overheat alarm.
Defines when the drive should declare a PF Fault.
When enabled the drive will sense cabin load prior to lifting
brake outputs, then pretorque motor to prevent rollback.
When enabled, this allows the maximum operating speed to
be limited under low mains voltage or when commanded via a
logic input
Function that will automatically decrease motor flux when the
output voltage reaches the saturation range.
Used to determine how the drive cooling fans will operate.
Sets if the drive will run at reduced PWM frequency when on
inspection control.
Sets if the drive will run at reduced PWM frequency when in
rescue operation.
Choices
– Immediate
– Rescue
– Run Remove
– Analog
– Serial HPV
– Option Card
– Disabled
– Enabled
– Pre-torque
– Feed Forward
– Alarm Only
– Fault
– Disabled
– Enabled
– Flt Outp Disabld
– Flt Outp Enabled
– Disabled
– 1PH Loss Det
– 2/3PH Loss
– DC-PH
– Enabled
– Disabled
– Disabled
– Enabled
– Enable at HBB
– Battery
– Single Phase UPS
– Three Phase UPS
Disabled
Enabled
Alarm Only
Ramp to Stop
Coast to Stop
En During Run
Disabled
En at Const Spd
Disabled
Enabled
Disabled
External TB
Low Mains
-Enabled,
-Disabled
,
,
<2>
<3>
<4>
– Run With Timer
– Run Always
– Temp Controlled
– 2kHz
– Default Carrier
– 2kHz
– Default Carrier
MAGNETEK HPV1000 AC Elevator Drive Technical Manual
Default
Rescue
Analo
,
<3>
<4>
Disabled
,
<3>
<4>
Pre-torque
,
<3>
<4>
Alarm Only
Disabled
,
<2>
<3>
Flt Outp Disabld
DC-PH
Enabled
Disabled
Single Phase UPS
Disabled
Alarm Only
Disabled
Disabled
Disabled
Enabled
,
<2>
<3>
Run With Timer
2kHz
2kHz