LifeSpan TURBO PLUS User Manual page 21

Table of Contents

Advertisement

Controller problem
1. Replace the controller
Over speed protection. (Sudden increase of running belt speed).
1. Check the speed sensor and magnet are in correct alignment and that there are no
obstructions on the magnet.
2. Check wire connections on the controller.
3. Replace the speed sensor.
4. Replace the controller.
Incline fault
1. Replace incline motor.
2. If problem remains replace controller.
When alarm signals are displayed, single press 'CLEAR' to reset the displays and try again.
No Power
1. Check fuses (They are located on the controller under the motor cover next to the
on/off switch.
2. Check power outlet (Plug something else into the power outlet to ensure that the
power outlet is working correctly).
3. Check Power Cable (You may need to take it to an electrician).
LIFESPAN TURBO PLUS