Specifications
Normal overload 110% for 1 minute
Frequency converter
Typical Shaft Output [kW]
IP20/NEMA Chassis
IP21/NEMA 1
IP55/NEMA 12
IP66
Output current
Continuous (3 x 525-550 V) [A]
Intermittent (3 x 525-550 V) [A]
Continuous (3 x 525-600 V) [A]
Intermittent (3 x 525-600 V) [A]
Continuous kVA (525 V AC) [kVA]
Continuous kVA (575 V AC) [kVA]
Max. input current
Continuous (3 x 525-600 V) [A]
Intermittent (3 x 525-600 V) [A]
Max. pre-fuses
Additional specifications
Estimated power loss at rated max. load [W]
Max. cable size (mains, motor, brake)
2
[mm
]/(AWG)
Weight enclosure IP20 [kg]
4)
Efficiency
Table 10.8 Mains Supply 3 x 525-600 V AC
1)
For type of fuse see 10.3.2 Fuse Tables
2)
American Wire Gauge
3)
Measured using 5 m screened motor cables at rated load and rated
10
10
frequency
4)
The typical power loss is at normal load conditions and expected
± 15% (tolerance relates to variety in voltage and cable
to be within
conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line).
Lower efficiency motors will also add to the power loss in the
frequency converter and vice versa.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
64
1)
[A]
4)
2)
MG20M902 - VLT
®
VLT
AQUA Drive
Operating Instructions
P15K
P18K
P22K
15
18.5
22
B3
B3
B4
B1
B1
B2
B1
B1
B2
B1
B1
B2
23
28
36
25
31
40
22
27
34
24
30
37
21.9
26.7
34.3
21.9
26.9
33.9
20.9
25.4
32.7
23
28
36
40
50
60
285
329
460
12
12
23.5
0.98
0.98
0.98
If the switching frequency is raised from nominal the power losses
may rise significantly.
LCP and typical control card power consumptions are included.
Further options and customer load may add up to 30 Watts to the
losses. (Though typically only 4 W extra for a fully loaded control
card or options for slot A or slot B, each).
Although measurements are made with state of the art equipment,
some measurement inaccuracy must be allowed for (
5)
Motor and mains cable: 300 MCM/150 mm
®
is a registered Danfoss trademark
P30K
P37K
P45K
P55K
30
37
45
55
B4
B4
C3
C3
B2
B2
C1
C1
B2
B2
C1
C1
B2
B2
C1
C1
43
54
65
87
47
59
72
96
41
52
62
83
45
57
68
91
41
51.4
61.9
82.9
40.8
51.8
61.7
82.7
39
49
59
78.9
43
54
65
87
80
100
150
160
560
740
860
890
[35]/(2)
[50]/(1)
23.5
23.5
35
35
0.98
0.98
0.98
0.98
P75K
P90K
75
90
C4
C4
C2
C2
C2
C2
C2
C2
105
137
116
151
100
131
110
144
100
130.5
99.6
130.5
95.3
124.3
105
137
225
250
1020
1130
[95
5)
]/( 3/0)
50
50
0.98
0.98
± 5%).
2