Specifications - Comtech EF Data XSAT-7080 Series Installation And Operation Manual

5 to 25, 50 & 100 watts
Table of Contents

Advertisement

XSAT7080 X-Band Transciever
+10 dBm Model X-Band Transceiver
8.2

Specifications

The following are the design, operating, and environmental specifications for the
XSAT-7080 unit.
Transmit
Frequency
Intermodulation
Total OPBO = 6 dB
SCL = 9 dB OPBO,
∆ = 1 MHz
TX Output Power, P1dB
TX Gain
TX Gain Flatness
TX Gain Stability
nd
2
Harmonic
Carrier Mute
Transmit Spurious:
AC Line Harmonics
Signal Related
Signal Related, In-Band
Signal Independent
AM to PM Conversion
IF Frequency Range
IF Input VSWR
RF Output VSWR
RF Output Impedance
IF Input Impedance
TX Noise Figure
IF Output Connector
IF Input/Output Connectors
7900 to 8400 MHz
- 45 dBc
+10 dBm
34 ± 1.0 dB
± 0.75 per 36 MHz
± 1.0 dB per 40 MHz
± 1.00 dB from –40 to +55°C
(-40 to 131°F)
-55 dBc
-70 dBc
-45 dBc
< 500 kHz, –60 dbc
-65 dBc
-55 dBm
3 degrees at 6 dB OPBO from
related power
70 ± 20 MHz
1.25:1
1.25:1
50 Ω
50 Ω
15 dB (Typical)
Type N (Female)
Type N (Female)
Receive
RX Fequency
RX Gain
RX-IF Frequency
Gain, without LNA
Gain Flatness
Image Rejection
RX Gain Stability, without
LNA, at 0 dBm Output Level
Output Power, P1dB
RX Noise Figure
Intermodulation
IF Output VSWR
RF Input VSWR
IF Output Impedance
RF Input Impedance
RF Input/Output Connectors
8–3
Revision 0
MN/XSAT7080.IOM
7250 to 7750 MHz
45 ± 1 dB
70 ± 18 MHz
70 ± 20 MHz (Optional)
140 ± 36 MHz (Optional)
± 0.75 dB Full RF Band
± 0.25 dB constant temp
± 0.75 dB Full RF Band
± 0.75 per 36 MHz
± 1.0 dB per 40 MHz
60 dB In-Band
± 0.25 dB Constant C
± 1.00 dB –40 to +55°C
(-40 to 131°F)
+13 dBm
11 dB (Typical
-50 dBc for two tones at
0 dBm each, 1 MHz apart
1.25:1
1.25:1
50 Ω
50 Ω
Type N (Female)