System Operation
3.1.2 C
ONNECTOR
Mating connector: ITT: KPT06J14-19P or MS3116J14-19P
Connections, see the following table:
Pin
Signal
A
EIA -485 +RX
B
EIA -485 –RX
C
EIA -485 TX+
D
EIA -485 TX-
E
EIA -232 Rd
F
REDUNDANT FAULT
G
EIA -232 Td
H
AUXCOM Rd
J
AUXCOM Td
K
FAULT COMMON
L
FAULT NORM OPEN
M
FAULT NORM CLOSED
N
ADDRESS SELECT
P
ONLINE STATUS
R
+24V AUX
S
REDUNDANCY
T
GROUND
U
GROUND
V
NO CONNECT
J5: COMM, R
EMOTE COMMUNICATIONS PORT
I/O
Input
Input
Output
Output
Input
Input
Output
Input
Output
Output
Output
Output
Input
Input
Output
Input
Passive
Passive
XSAT Receive Line
XSAT Receive Line Compliment
XSAT Transmit Line
XSAT Transmit Line Compliment
XSAT Receive Line
Redundant Controller Status Input
XSAT Transmit Line
Auxiliary RS232 Rd used with Redundant Controller
Auxiliary RS232 Td used with Redundant Controller
Open(OK) / Short(Fault)
Short(OK) / Open(Fault)
Redundant Addressing
Input from Redundant Controller
24V output to power Redundant Controller
Open (stand-alone) / Gnd (Redundancy)