Comtech EF Data XSAT-7080 Series Installation And Operation Manual page 50

5 to 25, 50 & 100 watts
Table of Contents

Advertisement

XSAT7080 X-Band Transceiver
Remote Control
Arguments
for
Command
Command
or
(Instruction
Parameter
Response
Code and
Type
to Query
qualifier)
Retrieve
N/A
37 bytes,
Redundancy
alpha
Status
numerical
Retrieve
N/A
175 bytes,
Maintenance
alpha
Status
numerical
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Query only.
Used to Query the utility status of the XSAT
Example: RRS='cr'
R 5V=5.0'cr'
R 12V=11.8'cr'
TX SW=OK'cr'
RX SW=OK'cr''lf'
Query only.
Used to Query the maintenance status of the XSAT
Example: RMS='cr'
24VT=023.9'cr'
20VT=020.3'cr'
12VT=012.0'cr'
10VT=010.2'cr'
P5VT=005.0'cr'
N5VT=-05.0'cr'
USYN=008.2'cr'
UIFL=003.9'cr'
DSYN=006.3'cr'
DIFL=003.8'cr'
REFV=002.9'cr'
LNAC=081.9'cr'
FANC=541.0'cr'
UTMP= 37.0'cr'
POWR=25.0-'cr'
DTMP= 34.0'cr''lf'
Response to
Command
(Slave to Master)
N/A
N/A
4-16
MN/XSAT7080.IOM
Query
(Instruction
Response to Query
code and
(Slave to Master)
qualifier)
RRS?
RRS=x....x (see description for
details of arguments)
RMS?
RMS=x....x (see description for
details of arguments)
Revision 0

Advertisement

Table of Contents
loading

Table of Contents