KROHNE OPTIWAVE 7300 C Handbook page 53

Radar level meter for distance, level and volume measurement of liquids, pastes and solids
Hide thumbs Also See for OPTIWAVE 7300 C:
Table of Contents

Advertisement

53
Function (Fct.)
C.3.6.0
HART address
C.5.0.0
Device setup
C.5.1.0
Display settings
C.5.1.1
Language
C.5.1.2
Display mode
C.5.1.3
Time delay
C.5.1.4
Length unit
C.5.1.5
Volume unit
C.5.1.6
Mass unit
C.5.1.7
Customer length unit
C.5.1.8
Customer length ratio 1 to 99999. 1
C.5.1.9
Customer conversion
unit
C.5.2.0
Passwords
C.5.2.1
Supervisor password
- Enable/disable
C5.2.2
Supervisor
Input Range
0 to 15. 0
American edition: English,
French, Spanish or
Portuguese; European
edition: English, German,
French, Spanish,
Portuguese or Italian;
Asian edition: English,
Japanese, Mandarin,
Russian. English
Disable, Auto-off or default
screen. -
1, 3, 5 or 10 minutes. 3
m, cm, mm, inch, ft,
ft+inch+1/18inch,
ft+inch+1/32inch or free
unit. m
m³, L, US gal, GB gal, ft³
or bbl. m³
Tons, kg, US tons or GB
tons. kg
9 characters max. Krohne Customer-defined length unit to be
9 characters max. -
Enable or disable. Enable Activates or deactivates device
6 characters max.using
kepad right(R), enter (E),
down (D) or up (U).
REDURE
OPTIWAVE 7300 C
Handbook OPTIWAVE 7300 C
Description
Any HART address greater than 0 will
enable HART Multidrop mode (current
output fixed at 4mA).
You will find the complete list of menu
items relating to the setup of the device
here. This includes parameters for Human
Machine Interface and measurement
value formats.
Sets device display characteristics.
Sets the language for readings and
configuration.
Defines the status of the display after a
given time delay. 'None' disables this
functionality, 'Auto-off' switches off the
display and 'Default screen' will show the
selected default screen. The default
screen can be selected in Normal mode
by pressing the down key for three
seconds.
Determines the time after which the
display will switch to the status set in
C.5.1.2 Display mode.
Displayed length unit in normal mode.
Displayed volume unit in normal mode.
Displayed mass unit in normal mode.
displayed.
Enter the factor between C.5.1.4 Length
unit selected and C.5.1.7 Customer length
unit. Relative to 1 m
A customer-defined conversion unit for
display/conversion table.
configuration protection (for all functions
listed in this section)
Modifies the supervisor password. To
confirm the change, the new password
must be entered twice.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents